A computer aided measurement method for unstable pelvic fractures based on standardized radiographs
نویسندگان
چکیده
BACKGROUND To set up a method for measuring radiographic displacement of unstable pelvic ring fractures based on standardized X-ray images and then test its reliability and validity using a software-based measurement technique. METHODS Twenty-five patients that were diagnosed as AO/OTA type B or C pelvic fractures with unilateral pelvis fractured and dislocated were eligible for inclusion by a review of medical records in our clinical centre. Based on the input pelvic preoperative CT data, the standardized X-ray images, including inlet, outlet, and anterior-posterior (AP) radiographs, were simulated using Armira software (Visage Imaging GmbH, Berlin, Germany). After representative anatomic landmarks were marked on the standardized X-ray images, the 2-dimensional (2D) coordinates of these points could be revealed in Digimizer software (Model: Mitutoyo Corp., Tokyo, Japan). Subsequently, we developed a formula that indicated the translational and rotational displacement patterns of the injured hemipelvis. Five separate observers calculated the displacement outcomes using the established formula and determined the rotational patterns using a 3D-CT model based on their overall impression. We performed 3D reconstruction of all the fractured pelvises using Mimics (Materialise, Haasrode, Belgium) and determined the translational and rotational displacement using 3-matic suite. The interobserver reliability of the new method was assessed by comparing the continuous measure and categorical outcomes using intraclass correlation coefficient (ICC) and kappa statistic, respectively. RESULT The interobserver reliability of the new method for translational and rotational measurement was high, with both ICCs above 0.9. Rotational outcome assessed by the new method was the same as that concluded by 3-matic software. The agreement for rotational outcome among orthopaedic surgeons based on overall impression was poor (kappa statistic, 0.250 to 0.426). Compared with the 3D reconstruction outcome, the interobserver reliability of the formula method for translational and rotational measures was perfect with both ICCs more than 0.9. CONCLUSIONS The new method for measuring displacement using a formula was reliable, and could minimise the measurement errors and maximise the precision of pelvic fracture description. Furthermore, this study was useful for standardising the operative plan and establishing a theoretical basis for robot-assisted pelvic fracture surgery based on 2-D radiographs.
منابع مشابه
The functional outcome of surgically treated unstable pelvic ring fractures by open reduction, internal fixation
Abstract Background: Unstable Pelvic fracture, a result of high energy antero-posterior compression injury, has been managed based on internal fixation and open reduction. The mode of fixation in Unstable Pelvic fracture has, however, been a subject of controversy and some authors have proposed a need to address the issue of partial breach of the pelvic ring elements in these injuries. This st...
متن کاملA Semi-Automatic Algorithm for Estimating Cobb Angle
Background: Scoliosis is the most common type of spinal deformity. A universal and standard method for evaluating scoliosis is Cobb angle measurement, but several studies have shown that there is intra- and inter- observer variation in measuring cobb angle manually.Objective: Develop a computer- assisted system to decrease operator-dependent errors in Cobb angle measurement.Methods: The spinal ...
متن کاملImproved Survival with a Standardized Multidisciplinary 3-in-1 Pelvic Damage Control Protocol for Hemodynamically Unstable Pelvic Fracture
Introduction: Haemodynamically unstable pelvic fracture carries a high mortality rate of up to 60%. Being one of the trauma centers in Hong Kong, we have been developing and modifying a protocol for unstable pelvic fracture since 1996, with continuous improvement in survival rate. In the most updated 3-in-1 Pelvic Damage Control Protocol, three different sources of bleeding, including bony, ven...
متن کاملUtility of plain film pelvic radiographs in blunt trauma patients in the emergency department.
The objective of this study was to evaluate the utility and sensitivity of routine pelvic radiographs (PXR) in the initial evaluation of blunt trauma patients. A retrospective review was performed. One hundred seventy-four patients with a pelvic fracture who had computed tomography (CT) and PXR were included (average age, 36.1; average Injury Severity Score, 16.3). Nine (5%) patients died. Five...
متن کاملPercutaneous iliosacral screw fixation in unstable pelvic fractures
Surgical treatment of unstable pelvic fractures Type C, has a vertical instability that is not controlled by traction and supine; therefore, orthopedic and functional treatments undertaken by default are sources of complications. The closed reduction with percutaneous sacroiliac fixation solves the problem of vertical instability; but at the cost of learning the method. Five patients with unsta...
متن کامل