Automated frame-by-frame endocardial border detection from cardiac magnetic resonance images for quantitative assessment of left ventricular function: validation and clinical feasibility.
نویسندگان
چکیده
PURPOSE To develop a technique based on image noise distribution for automated endocardial border detection from cardiac magnetic resonance (CMR) images throughout the cardiac cycle, validate it, and test its clinical utility. MATERIALS AND METHODS Images obtained in 36 patients were analyzed using custom software to obtain left ventricular (LV) volume throughout the cardiac cycle, end-systolic and end-diastolic LV volumes, and ejection fraction (EF). Validation against manually-traced endocardial boundaries included intertechnique comparisons of LV volumes, slice areas, and border positions. Then, the clinical feasibility of the dynamic automated analysis of LV function was tested in 14 patients with normal LV function, 12 patients with systolic dysfunction, and 10 patients with diastolic dysfunction. RESULTS Analysis time for one cardiac cycle was <15 minutes. Intertechnique comparisons resulted in high correlation (r>0.96), small biases (volumes: -6 mL; EF: 4.6%) and narrow limits of agreement (volumes: 17.6 mL; EF: 9.2%). We found significant intergroup differences in multiple quantitative indices of systolic and diastolic function. CONCLUSION Fast, automated, dynamic detection of LV endocardial boundaries is feasible and allows accurate quantification of LV size and function, which is potentially clinically useful for objective assessment of systolic and diastolic dysfunction.
منابع مشابه
Mitral valve E-Point to Septal Separation (EPSS) measurement by cardiac magnetic resonance Imaging as a quantitative surrogate of Left Ventricular Ejection Fraction (LVEF)
Background Using Echocardiography, the mitral Valve E-Point to Septal Separation (EPSS) is a straightforward approach that roughly corresponds to the status of left ventricular (LV) function, but its use has been limited to echocardiography and without solid quantitative correlation to left ventricular ejection fraction (LVEF). It may also cause underestimation of EF due to endocardial echo dro...
متن کاملAutomated interpretation of regional left ventricular wall motion from cardiac magnetic resonance images.
UNLABELLED Magnetic resonance (MR) diagnosis of regional left ventricular (LV) dysfunction relies on visual interpretation of cine images that suffers from wide inter-observer variability, especially when performed by readers not specifically trained in the assessment of LV wall motion. Quantitative analysis tools, though widely available, are rarely used because they provide large amounts of d...
متن کاملEndocardial Border Detection in Contrast Enhanced Echocardiographic Cineloops using a Pulse Coupled Neural Network
Endocardial border detection is a crucial step for the quantitative analysis of overall and regional left ventricular function from echocardiographic images. Echocardiographic contrast agents with transpulmonary passage are being used increasingly in clinical practice for left ventricular cavity opacification. We investigate the feasibility of using pulse coupled neural networks to identify the...
متن کاملDetecting left ventricular impaired relaxation in cardiac MRI using moving mesh correspondences
UNLABELLED Anatomical cine cardiovascular magnetic resonance (CMR) imaging is widely used to assess the systolic cardiac function because of its high soft tissue contrast. Assessment of diastolic LV function has not regularly been performed due the complex and time consuming procedures. This study presents a semi-automated assessment of the left ventricular (LV) diastolic function using anatomi...
متن کاملThe role of still-frame parametric imaging in magnetic resonance assessment of left ventricular wall motion by non-cardiologists.
BACKGROUND Cardiac magnetic resonance (MR) images are often reviewed by non-cardiologists who are not trained in the interpretation of regional left ventricular (LV) function. We hypothesized that the use of still-frame parametric MR images of wall motion could aid in the assessment of regional LV function. METHODS Dynamic, electrocardiogram-gated, steady-state free precession (FIESTA) short-...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of magnetic resonance imaging : JMRI
دوره 29 3 شماره
صفحات -
تاریخ انتشار 2009