Evaluation of a lysis direct plating method for pediatric blood cultures.

نویسندگان

  • D F Welch
  • R K Scribner
  • D Hensel
چکیده

The Isolator 1.5 Microbial tube (E. I. du Pont de Nemours & Co., Inc., Wilmington, Del.) is a commercially available blood culture system for use in pediatrics. The methodology is based on blood lysis followed by direct plating of the sample on culture media to detect bacteria and fungi. Comparative recovery rates of pathogens from blood collected in this and a conventional broth system were similar. The Isolator detected 104 of 120 clinically significant isolates, whereas 106 of 120 isolates were detected by the broth system. The major advantage of the Isolator methodology was early detection of septicemia. Initial detection of gram-negative bacteria occurred an average of 14.2 h earlier by the Isolator system than by the conventional broth method. The Isolator also permitted quantitation of bacteremia and fungemia. Probable contaminants were recovered from 10.0% of the cultures processed by the Isolator, but steps which could be taken to minimize this problem were identified. The Isolator is a useful method for pediatric blood cultures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of blood culture methods for recovery of Legionella pneumophila from the blood of guinea pigs with experimental infection.

Blood was cultured from guinea pigs with experimental Legionella pneumophila serogroup 1 pneumonia, using four different methods. A 0.03-ml amount was spread onto each of several plates of buffered charcoal-yeast extract supplemented with alpha-ketoglutarate (BCYE) (direct plate); 1.5 ml each was inoculated into a BCYE agar-yeast extract broth bottle (biphasic), a pediatric Isolator tube (E. I....

متن کامل

Recovery of Gardnerella vaginalis from blood by the quantitative direct plating method.

This report describes a case of Gardnerella vaginalis sepsis in an obstetric patient whose blood cultures were negative by the conventional BACTEC system but positive by the quantitative direct plating method, which involves the direct inoculation of blood samples on chocolate agar and blood agar plates.

متن کامل

Diagnosis of disseminated mycobacterial infection: testing a simple and inexpensive method for use in developing countries.

With the development of the acquired immunodeficiency syndrome (AIDS) epidemic, the isolation of mycobacteria from blood has become a common problem for clinical laboratories. In this study two methods were used for the recovery of mycobacteria from blood specimens obtained from AIDS patients: (1) direct inoculation of a biphasic medium, and (2) a non-commercial lysis-centrifugation method. A t...

متن کامل

Clinical comparison of the Isolator 1.5 microbial tube and the BACTEC radiometric system for detection of bacteremia in children.

The Isolator 1.5 microbial tube (E. I. du Pont de Nemours & Co., Inc., Wilmington , Del.) was compared with the BACTEC radiometric detection system (Johnston Laboratories, Inc., Cockeysville, Md.) for the detection of bacteremia in children. The Isolator 1.5 is a blood culture system designed for small volumes of blood (0.5 to 1.5 ml). The method involves lysis of the cells of the patient and t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 21 6  شماره 

صفحات  -

تاریخ انتشار 1985