Gated F-18 FDG PET for Assessment of Left Ventricular Volumes and Ejection Fraction Using QGS and 4D-MSPECT in Patients with Heart Failure: A Comparison with Cardiac MRI

نویسندگان

  • Yan Li
  • Li Wang
  • Shi-Hua Zhao
  • Zuo-Xiang He
  • Dao-Yu Wang
  • Feng Guo
  • Wei Fang
  • Min-Fu Yang
چکیده

PURPOSE Ventricular function is a powerful predictor of survival in patients with heart failure (HF). However, studies characterizing gated F-18 FDG PET for the assessment of the cardiac function are rare. The aim of this study was to prospectively compare gated F-18 FDG PET and cardiac MRI for the assessment of ventricular volume and ejection fraction (EF) in patients with HF. METHODS Eighty-nine patients with diagnosed HF who underwent both gated F-18 FDG PET/CT and cardiac MRI within 3 days were included in the analysis. Left ventricular (LV) end-diastolic volume (EDV), end-systolic volume (ESV), and EF were obtained from gated F-18 FDG PET/CT using the Quantitative Gated SPECT (QGS) and 4D-MSPECT software. RESULTS LV EDV and LV ESV measured by QGS were significantly lower than those measured by cardiac MRI (both P<0.0001). In contrast, the corresponding values for LV EDV for 4D-MSPECT were comparable, and LV ESV was underestimated with borderline significance compared with cardiac MRI (P = 0.047). LV EF measured by QGS and cardiac MRI showed no significant differences, whereas the corresponding values for 4D-MSPECT were lower than for cardiac MRI (P<0.0001). The correlations of LV EDV, LV ESV, and LV EF between gated F-18 FDG PET/CT and cardiac MRI were excellent for both QGS (r = 0.92, 0.92, and 0.76, respectively) and 4D-MSPECT (r = 0.93, 0.94, and 0.75, respectively). However, Bland-Altman analysis revealed a significant systemic error, where LV EDV (-27.9±37.0 mL) and ESV (-18.6±33.8 mL) were underestimated by QGS. CONCLUSION Despite the observation that gated F-18 FDG PET/CT were well correlated with cardiac MRI for assessing LV function, variation was observed between the two imaging modalities, and so these imaging techniques should not be used interchangeably.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation of QGS and 4D-MSPECT for quantification of left ventricular volumes and ejection fraction from gated 18F-FDG PET: comparison with cardiac MRI.

UNLABELLED The aim of this study was to validate Quantitative Gated SPECT (QGS) and 4D-MSPECT for assessing left ventricular end-diastolic and systolic volumes (EDV and ESV, respectively) and left ventricular ejection fraction (LVEF) from gated (18)F-FDG PET. METHODS Forty-four patients with severe coronary artery disease were examined with gated (18)F-FDG PET (8 gates per cardiac cycle). EDV...

متن کامل

Gated myocardial perfusion SPECT: algorithm-specific influence of reorientation on calculation of left ventricular volumes and ejection fraction.

UNLABELLED Gated myocardial perfusion SPECT allows calculation of end-diastolic and end-systolic volumes (EDV and ESV, respectively) and left ventricular ejection fraction (LVEF). The quantification algorithms QGS (quantitative gated SPECT), 4D-MSPECT, and CARE heart show a good correlation with cardiac MRI. Nevertheless, differences in contour finding suggest algorithm-specific effects if hear...

متن کامل

Model-based analysis of electrocardiography-gated cardiac (18)F-FDG PET images to assess left ventricular geometry and contractile function.

UNLABELLED This study presents and evaluates a model-based image analysis method to calculate from gated cardiac (18)F-FDG PET images diastolic and systolic volumes, ejection fraction, and myocardial mass of the left ventricle. The accuracy of these estimates was delineated using measurements obtained by MRI, which was considered the reference standard because of its high spatial resolution. ...

متن کامل

WHITE PAPER Validation of a deformable atlas-based left ventricular segmentation method for PET and SPECT: comparison to cardiac computed tomography angiography (CCTA) volumes

Gated myocardial perfusion SPECT and PET are commonly used to calculate left ventricular ejection fraction (LVEF) and assess left ventricular end diastolic (EDV) and end systolic volumes (ESV). A number of software methods have been developed to automatically calculate these parameters. In a previous work we compared the LV parameters (EF, EDV, ESV) for three software packages: MIMcardiac®, QGS...

متن کامل

Left ventricular functional assessment in murine models of ischemic and dilated cardiomyopathy using [18 F]FDG-PET: comparison with cardiac MRI and monitoring erythropoietin therapy

BACKGROUND We performed an initial evaluation of non-invasive ECG-gated [18 F]FDG-positron emission tomography (FDG-PET) for serial measurements of left ventricular volumes and function in murine models of dilated (DCM) and ischemic cardiomyopathy (ICM), and then tested the effect of erythropoietin (EPO) treatment on DCM mice in a preliminary FDG-PET therapy monitoring study. METHODS Mice dev...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014