Routine preparation of seminal fluid specimens for transmission electron microscopy.
نویسندگان
چکیده
A technique is described for the routine preparation of seminal fluid specimens for transmission electron microscopy. The method is applicable to cases where examination of sperm morphology is required and can also be used for the indentification of non-spermatozoal cells and their inclusions.
منابع مشابه
Transmission Electron Microscopy Sample Preparation of INCONEL 738 Nickel-Base Superalloy
Size, shape, volume fraction and distribution of embedded g/ phase in g phase has direct effect on strength of INCONEL alloy. Microstructure parameters of INCONEL phases are quantified from microstructure images using transmission electron microscopy (TEM). Different TEM sample preparation techniques were used to study INCONEL 738 alloy microstructure for transmission electron micros...
متن کاملTransmission Electron Microscopy of Lipid Vesicles in Liquid Cells
Liquid cell transmission electron microscopy (TEM) shows promise for enabling nanometer-scale imaging of fluid-hydrated biological material by enclosing specimens within windowed devices [1]. However, the thickness of the liquid cell reduces the signal-to-noise ratios of acquired images, a particular problem for researchers imaging biological specimens. Thus investigators typically image biolog...
متن کاملFocused ion beam preparation of atom probe specimens containing a single crystallographically well-defined grain boundary.
Needle-shaped atom probe specimens containing a single grain boundary were produced using the focused ion beam (FIB) of a two-beam FIB/SEM (scanning electron microscope) system. The presented specimen preparation approach allows the unprecedented study of a grain boundary which is well characterised in its crystallographic orientation by means of the field ion microscope (FIM) and the tomograph...
متن کاملPreparation and Utilization of MnO2 Nanoparticles (NPs) Catalyst for the Decontamination against Chemical Warfare Nerve Agent Simulant (CWNAS)
In this scientific research, MnO2 nanoparticles (NPs) have been successfully prepared by a precipitation method using KMnO4, MnSO4.H2O and H2O2 (30%) as the precursors. As-prepared sample was identified by X-ray diffraction (XRD), Scanning electron microscopy (SEM), Transmission electron microscopy (TEM) and Infrared (IR) techniques. The transmission electron microscopy (TEM) showed 7-8 nm rang...
متن کاملPreparation and Utilization of MnO2 Nanoparticles (NPs) Catalyst for the Decontamination against Chemical Warfare Nerve Agent Simulant (CWNAS)
In this scientific research, MnO2 nanoparticles (NPs) have been successfully prepared by a precipitation method using KMnO4, MnSO4.H2O and H2O2 (30%) as the precursors. As-prepared sample was identified by X-ray diffraction (XRD), Scanning electron microscopy (SEM), Transmission electron microscopy (TEM) and Infrared (IR) techniques. The transmission electron microscopy (TEM) showed 7-8 nm rang...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical pathology
دوره 34 9 شماره
صفحات -
تاریخ انتشار 1981