Precise Half - Life Measurement of 22 Mg

نویسندگان

  • V. E. Iacob
  • J. C. Hardy
  • M. Sanchez-Vega
  • A. Azhari
  • C. A. Gagliardi
  • E. V. Mayes
  • R. G. Neilson
چکیده

As part of our program [1] to test CKM unitarity via superallowed ∃-decays, we reported in last year’s Progress Report [2] that we were well advanced in making a measurement of the half-life of Mg. At that time we had obtained a preliminary result but had not yet fully explored all possible systematic errors. Subsequently, an additional experiment was performed at the MARS spectrometer with our fast tape-transport system. It was carried out under similar conditions to those reported previously [2], but incorporated a variety of parameter changes focused on exposing unexpected systematic effects if they are present. As before [2], a beam of 23 AMeV Mg (pure to better than 99.6%) exited the MARS spectrometer, was degraded and then implanted in mylar tape. The purity of the collected sample was enhanced further by the implantation, since any impurities have a different range and, thus, for the most part, do not stop in the tape. After a suitable collection time, the beam was turned off and the tape moved to convey the collected activity, within 190 ms, to the center of a 4Β proportional gas counter, from which the ∃decay signals were multi-scaled. Since deadtime is an important consideration in any precise half-life determination, we introduce into the circuit a fixed, non-extendable and welldetermined dead-time that is chosen to be larger than any of the other dead-times present there. This dominant dead-time can be changed from measurement to measurement. Data were collected under two different collect-time/counttime conditions: 8s/80s and 60s/160s. The first setting was optimized for the measurement of the Mg decay and is similar to the previous experiment [2]: about 20 million ∃-decay events were recorded in a sequence of measurements, each with a different setting of the detector bias, discriminator level, and/or dominant dead-time. The latter could be set to 8, 10, or 12:s. No systematic effects on the measured half-life could be detected. The second collect-time/count-time setting, 60s/160s, was optimized towards the detection and measurement of any possible impurity of comparable half-life present in our experiment: in particular, we were looking for Na (t1/2 = 22.48 s). About 5 x 10 events were collected in this configuration; these data revealed the presence of Na in the collected samples at a level of about 2 x 10 times that of Mg. Even though this might seem to be a small contamination, its effect on our result for the Mg half-life exceeds our statistical error and it certainly must be accommodated. With this result in mind, we have also revisited the previous measurements. The particle spectra recorded in the July 2000 run showed that the Na impurity in that measurement was about four times smaller than in the 2001 run (consistent with a narrower slitsetting of the MARS spectrograph for the July 2000 run). With the effects of Na accounted for, there is complete agreement between our results from the measurements in 2000 and in 2001. Combining both, we obtain a final value for the Mg half-life of t1/2 = 3.8749(12) s.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Processing Digital Image for Measurement of Crack Dimensions in Concrete

The elements of the concrete structure are most frequently affected by cracking. Crack detection is essential to ensure safety and performance during its service life. Cracks do not have a regular shape, in order to achieve the exact dimensions of the crack; the general mathematical formulae are by no means applicable. The authors have proposed a new method which aims to measure the crack dimen...

متن کامل

KINETICS AND MECHANISM OF AERIAL OXIDATION OF HYDROQUINONE IN A DEVELOPER SOLUTION AND DETERMINATION OF DEVELOPER'S HALF-LIFE AT 20°C

The aerial oxidation of hydroquinone in a freshly prepared developer solution at 20°C has been studied through the measurement of concentration changes by a spectrophotometric method. The concentration of consumed hydroquinone is directly proportional to time, and the equation tIl2 = C, / 0.0786 was obtained to calculate the half-life of the developer. In this equation, the half-life is in ...

متن کامل

The transfer half-life of morphine-6-glucuronide from plasma to effect site assessed by pupil size measurement in healthy volunteers.

BACKGROUND Clinical and experimental data suggested a long delay between the plasma concentration versus time course of morphine-6-glucuronide and the time course of its central opioid effects. This study was aimed at the quantification of the transfer half-life (t(1/2,ke0)) of this delay. METHODS Pupil size was used as a measure of central opioid effect. Eight healthy volunteers (four men, f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002