Planning of HIFU therapies of moving organs by using numerical simulation techniques

نویسندگان

  • Joachim Georgii
  • Caroline von Dresky
  • Daniel Demedts
  • Christian Schumann
  • Tobias Preusser
چکیده

Background We present a software prototype that allows for preinterventional planning and simulation of focused ultrasound therapies. By using numerical simulation techniques the heating and destruction of the tissue can be predicted and thus a patient-specific treatment plan can be generated in advance. Since our simulation is amenable to respect rib shielding, organ motion as well as focal point tracing, it could in particular support the planning of liver treatments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accounting for sliding motion in fast numerical simulations of abdominal HIFU applications for targets under respiratory motion

Background/introduction Non-invasive ablation and hyperthermia treatments of abdominal organs using High Intensity Focused Ultrasound (HIFU) still impose severe challenges. Especially for liver and kidney treatments, the target motion and accessibility over the entire respiratory cycle make the application of HIFU difficult. To allow for a safe, effective, and efficient treatment, detailed plan...

متن کامل

Numerical Simulation of Flow Past Oscillating Airfoil Using Oscillation of Flow Boundary Condition

The present study is devoted to an approximate modeling for numerical simulation of flows past oscillating airfoils. In this study, it is shown that the harmonic oscillating objects can be studied by simple numerical codes that are not able to solve moving grids. Instead of using moving grid for the simulation of flowfield around an oscillating airfoil, this unsteady flow is solved on a fixed g...

متن کامل

Numerical Study for Optimizing Parameters of High-Intensity Focused Ultrasound-Induced Thermal Field during Liver Tumor Ablation: HIFU Simulator

Introduction High intensity focused ultrasound (HIFU) is considered a noninvasive and effective technique for tumor ablation. Frequency and acoustic power are the most effective parameters for temperature distribution and the extent of tissue damage. The aim of this study was to optimize the operating transducer parameters such as frequency and input power in order to acquire suitable temperatu...

متن کامل

HIFU Therapy Planning Using Pre‐treatment Imaging and Simulation

Current HIFU challenges include amount of tissue that can be destroyed by a single exposure, the inability to treat through bone, difficulty in monitoring therapy in real‐time, and difficulty in planning the strategy before therapy. Technological advances such as multi‐transducer or array beam generator, instrumentation and image‐based guidance of HIFU treatment promise to overcome many of thes...

متن کامل

Numerical Simulation of Flash Boiling Effect in a 3-Dimensional Chamber Using CFD Techniques

 Flash Boiling atomization is one of the most effective means of generating a fine and narrow-dispersed spray. Unless its complexity its potential has not been fully realized. In This Paper, a three dimensional chamber has been modeled with a straight fuel injector. Effect of Flash Boiling has been investigated by computational fluid dynamics (CFD) techniques. A finite volume approach with the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2014