Automated simultaneous quantification of the immunosuppressants 40-O-(2-hydroxyethyl) rapamycin and cyclosporine in blood with electrospray-mass spectrometric detection.
نویسندگان
چکیده
A new analytical method to quantify 40-O-(2-hydroxyethyl)rapamycin (SDZ RAD) and cyclosporine (Cs) simultaneously in blood is presented. The combination of an on-line solid-phase extraction step with an HPLC system coupled to an electrospray mass spectrometer gave excellent specificity, sensitivity, and reproducibility. Aliquots of deproteinized blood samples were injected into the HPLC system and extracted on-line, using a conventional C18 guard column. The extract was eluted from the guard column in the backflush mode and injected into the liquid chromatography-mass spectrometry system. The calibration functions for SDZ RAD and Cs extracted from blood with added analyte were linear from 0.15 to 30 microg/L (r2 = 0.999) and from 1.5 to 1000 microg/L (r2 = 0.999), respectively. The CVs of peak areas were 6.2% at 10 microg/L SDZ RAD (n = 6) and 6.2% at 100 microg/L Cs (n = 6). Recovery ranged from 84.3% to 102.3% for SDZ RAD and from 81.7% to 92.2% for Cs. The lower limit of detection for both drugs was 0.05 microg/L. A rate of four samples per hour was maintained during the consecutive analysis of SDZ RAD and Cs in >500 blood samples with one single extraction and analytical column. The method described is a powerful tool for the simultaneous determination of SDZ RAD and Cs in blood. It works without time-consuming sample preparation steps and with excellent reproducibility. Because of the detection performance of electrospray mass spectrometry, this system offers flexibility in the working range, which is essential for therapeutic drug monitoring under different conditions.
منابع مشابه
Inflammatory markers and cardiovascular risk in healthy polish women across the menopausal transition.
1. Armstrong VW, Oellerich M. New developments in the immunosuppressive drug monitoring of cyclosporine, tacrolimus, and azathioprine. Clin Biochem 2001;34:9–16. 2. Kahan BD, Keown P, Levy GA, Johnston A. Therapeutic drug monitoring of immunosuppressant drugs in clinical practice. Clin Ther 2002;24:330–50. 3. Oellerich M, Armstrong VW. Two-hour cyclosporine concentration determination: an appro...
متن کاملIdentification of a new metabolite of macrolide immunosuppressant, like rapamycin and SDZ RAD, using high performance liquid chromatography and electrospray tandem mass spectrometry.
Previously unknown metabolites from the two macrolide immunosuppressants rapamycin (sirolimus) and SDZ RAD [40-O-(2-hydroxyethyl)rapamycin] obtained after in vitro incubation with human liver microsomes have been purified. Structure elucidation was performed by nanoelectrospray ionization tandem mass spectrometry applying low energy collision activated dissociation. This ionization method is, a...
متن کاملValidation of an UHPLC-MS/MS method for simultaneous analysis of 11 mycotoxins in wheat flour Using Immunoaffinity column
This study focuses on optimization and validation of an Ultrahigh-performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method for simultaneous analysis of 11mycotoxins: Aflatoxin B1, T-2 Toxin, Ochratoxin A, Deoxynivalenol and Zearalenone in wheat matrix. Sample extraction and cleanup procedure is based on a single extraction step using acetonitrile/water/acetic acid mixture...
متن کاملValidation of an UHPLC-MS/MS method for simultaneous analysis of 11 mycotoxins in wheat flour Using Immunoaffinity column
This study focuses on optimization and validation of an Ultrahigh-performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method for simultaneous analysis of 11mycotoxins: Aflatoxin B1, T-2 Toxin, Ochratoxin A, Deoxynivalenol and Zearalenone in wheat matrix. Sample extraction and cleanup procedure is based on a single extraction step using acetonitrile/water/acetic acid mixture...
متن کاملSimultaneous detection of five different 2-hydroxyethyl-DNA adducts formed by ethylene oxide exposure, using a high-performance liquid chromatography/electrospray ionisation tandem mass spectrometry assay.
A method has been developed for the simultaneous detection and quantitation of five different 2-hydroxyethyl-DNA (HE-DNA) adducts that could be formed as a result of exposure to ethylene oxide (EO). In addition to the major N7-HE-guanine (N7-HEG) adducts this assay can also measure the less prevalent but potentially more biologically significant N1-HE-2'-deoxyadenosine (N1-HEdA), O(6)-HE-2'-deo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 44 6 Pt 1 شماره
صفحات -
تاریخ انتشار 1998