Geometric model of the structure of the neutron
نویسنده
چکیده
The paper examines the geometrical properties of a six-dimensional KaluzaKlein type model. They may have an impact on the model of the structure of a neutron and its excited states in the realm of one particle physics. The statistical reason for the six-dimensionality and the stability of the solution is given. The derivation of the weak limit approximation of the general wave mechanical (quantum mechanical) approach, defined in the context of losing its self-consistency (here gravitational), is presented. The non self-consistent case for the Klein-Gordon equation is defined. The derivation of the energy of states and the analysis of the spin origin of the analyzed fields configuration is presented as the manifestation of both the geometry of the internal two-dimensional space and kinematics of fields inside it. The problem of the departure from the (gravitational) self-consistent calculations of the metric tensor and of other fields of the configuration is discussed. The implementation of the model for the description of a neutron and its excited states, including their spins and energies, is given. The informational reason for the existence of the internal extra space dimensions is proposed.
منابع مشابه
An investigation of neutron direct damages at energies of 0.1-2 MeV on the DNA molecules with atomic structure deduced using Geant4 toolkit
This study proposes a method to estimate RBE of fast neutrons using Monte Carlo simulations. This approach is based on the combination of an atomic resolution DNA geometrical model and Monte Carlo simulations for tracking particles. Atomic positions were extracted from the Protein Data Bank. The GEANT4 code was used for tracking the secondary particles generated by fast neutrons during their in...
متن کاملDifferent Magnetic Field Distributions in Deformed Neutron Stars
In this work, we review the formalism which would allow us to model magnetically deformed neutron stars. We study the effect of different magnetic field configurations on the equation of state (EoS) and the structure of such stars. For this aim, the EoS of magnetars is acquired by using the lowest order constraint variational (LOCV) method and employing the AV18 potential....
متن کاملA COMPARISON BETWEEN THERMAL AND X RADIOGRAPHY FOR STUDYING THE INTERNAL STRUCTURE OF BIOLOGICAL
ABSTRACT Background: With respect to the difference in the interaction of thermal neutron and X rays with matter, using two radiography systems of thermal neutron and X rays will yield highly valuable information for studying the inner structure of biologic samples. Methods: The high sensitivity of thermal neutron to hydrogen, in particular, has led to recognizing this system as a useful tool ...
متن کاملModeling the measurement of VVER-1000 reactor power by neutron and gamma radiation with MCNP code
The present study deals with a new method for measuring the power of a reactor. This method uses gamma and neutron radiation resulted from the entire reactor structure, without changing its structure (online). In terms of functionality, this method can measure the reactor power in real-time and report it instantly. In order to obtain the relationship between reactor power and gamma and neutron ...
متن کاملCancer Risk Assessment due to Accidental Exposure inside Neutron Laboratories using BEIR VII Model
Introduction: Environmental and occupational human exposure from neutron source can lead to the serious biologic effects. The aim of this study is to evaluate the cancer incidence risk for various human organs at different neutron dose levels due to exposure from an Americium-241/Beryllium (Am-241/Be), a standard neutron source for calibration purposes. Material and Methods: We measured ambient...
متن کاملDosimetry Impact of Boron and Its Carriers Structure at Boron Neutron Capture Therapy of a Brain Tumor; A Sim- ulation Study
Introduction: Boron neutron capture therapy (BNCT) is a method of cancer treatment and potentially, two borono-L-phenylalanine (BPA) and sodium borocaptate (BSH) are used in BNCT as common boron carriers. Some previous studies have shown that the dose rate is directly related to boron concentration in the tissue. This study aimed to simulate the structure of boron carriers and brain tumor compo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2009