The Polarity Effect and the Corona Current in Small Air Gaps

نویسندگان

  • Athanasios L. Maglaras
  • Leandros A. Maglaras
چکیده

Abstract. A new approach of the Polarity Effect in connection to the Corona Current and the Ground Effect in small rod-plate and rod-rod air gaps is presented. The influence of the polarity of the applied voltage to the corona onset voltage or the breakdown voltage of small rod-plate and rod-rod air gaps is investigated. The influence of the grounding of one of the electrodes, to the field distribution, and consequently to the corona onset and the breakdown voltage of small air gaps, is also investigated by simulation analysis along with experimental work. This phenomenon is the Ground Effect, and is quite different from the Polarity Effect, though slightly influenced by it. The inhomogeneity of the electric field and the maximum values of the field strength in a rod-plate and rod-rod air gap are analogically higher when the plate is grounded and lower when the electrodes are symmetrically charged, or the rod is grounded. The values of the corona onset and the breakdown voltage in small air gaps are analogically lower for the arrangement with the plate grounded. Correspondent relations are valid for the rod-rod arrangements. In longer air gaps the corona current appears, the Polarity Effect becomes very intense and the Ground Effect is overlapped. Relations between the values of the breakdown voltage, the polarity of the applied voltage, the corona current through the gap and the way the gap is grounded are established. The principle of action-reaction is valid. “The corona current reacts against the action of the field to produce corona charges and makes the field less inhomogeneous”.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The influence of the Corona Current to the Ground and the Polarity Effect of small air gaps

The Corona Current in air gaps influences the values of the breakdown voltage of the air gaps greatly. This happens because the corona current changes the field distribution in the gap making it less inhomogeneous. Thus the value of the breakdown voltage increases and becomes bigger as the value of the corona current increases. A major result of this phenomenon is the appearance of the Polarity...

متن کامل

Determination of Electric Field at Inception Based upon Current-Voltage Characteristics of AC Corona in Rod-Plane Gaps

This paper deals with the measurement of AC corona inception voltage, Vincp, at the tip of a rod electrode using a hemispherically-capped rod-plane electrode configuration for various rod radii with a short air gap. Effects of atmospheric pressure and temperature variation on Vincp are investigated experimentally. An empirical equation for the field form factors of the hemispherically cappe...

متن کامل

An Experimental Study of the Effect of High Electric Field on Mass Transfer Enhancement

Applying corona wind as a novel technique can lead to a great level of heat and mass transfer augmentation by using a very small amount of energy. The enhancement of forced flow evaporation rate by applying electric field (corona wind) has been experimentally evaluated in this study. Corona wind produced by a fine wire electrode charged with positive high DC voltage impinges on water surface an...

متن کامل

Calculation of air gaps between bolus and skin on the dose received from the skin

    Introduction: In the last few decades, a lot of monte carlo codes have been introduced for medical applications. For close - to - surface tumors, the surface of the skin can be used to increase the surface dose so that all or part of the bunch area can fall into bolus, thereby increasing the dose of the skin. The air gaps between bolus and skin can affect the dose of...

متن کامل

Effect of coronavirus (Covid-19) pandemic on biological air pollutants: a case study of Valiasr hospital in Zanjan (2019-2020)

Background and Objective: Bioaerosols as small particles enter the body by inhalation and lead to respiratory diseases based on type, concentration, and exposure time. In sensitive workplaces such as medical centers, it is necessary to pay attention to the type and population of these pollutants and the possibility of nosocomial infections. In the present study, the population and type of bioae...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012