The scanning microbeam PIXE analysis facility at NIRS

نویسندگان

  • Hitoshi Imaseki
  • Masae Yukawa
  • Frank Watt
  • Takahiro Ishikawa
  • Hiroyuki Iso
  • Tsuyoshi Hamano
  • Kenichi Matsumoto
  • Nakahiro Yasuda
چکیده

In March 1999, a HVEE Tandetron was installed in the Electrostatic Accelerator Building of National Institute of Radiological Sciences (NIRS) for particle induced X-ray emission (PIXE) analysis. The specifications of the Tandetron accelerator system operating at NIRS are as follows: the accelerating voltage is 0.4–1.7 MV, and the maximum beam current is 500 nA at 3.4 MeV. The accelerator facility incorporates three beam lines for conventional, in-air and microbeam PIXE analysis. The scanning microbeam PIXE analysis line is based around an Oxford Microbeams OM2000 nuclear microscope end stage. This system provides the ability of multi-elemental mapping over sample areas up to 2 2 mm area with spatial resolutions routinely at 1 1 lm. The scheduled operation of this facility started in April 2000 and is controlled by the Division of Technical Service and Development. The result of beam resolution tests carried out in 2001 are as follows: for scanning transmission ion microscopy, the estimated beam size is 100 200 nm, measured using a 2.6 MeV proton beam scanned over a 12.7 lm repeat distance copper grid. For PIXE operation at 50 pA beam current the estimated best spot size is 0.4 0.6 lm. The microbeam facility is being used for research into the elemental distribution of small biological samples such as biological cells and tissue. 2003 Elsevier B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of Microbeam at Jaea Takasaki

The TIARA facilities of JAEA in Takasaki is equipped with a several-MeV light-ion and a several-dozen-MeV heavy-ion microbeam formation systems of focusing type, and a several-hundred-MeV heavy-ion microbeam formation system of collimating type. The microbeams with a spot size of 1 μm or less in diameter are extensively utilized for the research in materials science and biotechnology. An in-air...

متن کامل

Nuclear microprobe analysis and imaging: Current state of the art performances

The current state-of-the-art performances claimed for nuclear microbeam spatial resolutions are: (a) 400 nm spot sizes for high current (100 pA) proton beams, (b) 400 nm for high current alpha particle beams, (c) 100 nm for low proton current (co.1 PA) applications such as Scanning Transmission Ion Microscopy (STIM) and Ion Beam Induced Charge (IBIC) and (d) 50 nm for low current alpha particle...

متن کامل

SPICE-NIRS Microbeam: a focused vertical system for proton irradiation of a single cell for radiobiological research

The Single Particle Irradiation system to Cell (SPICE) facility at the National Institute of Radiological Sciences (NIRS) is a focused vertical microbeam system designed to irradiate the nuclei of adhesive mammalian cells with a defined number of 3.4 MeV protons. The approximately 2-μm diameter proton beam is focused with a magnetic quadrupole triplet lens and traverses the cells contained in d...

متن کامل

The Columbia University proton-induced soft x-ray microbeam.

A soft x-ray microbeam using proton-induced x-ray emission (PIXE) of characteristic titanium (K(α) 4.5 keV) as the x-ray source has been developed at the Radiological Research Accelerator Facility (RARAF) at Columbia University. The proton beam is focused to a 120 μm × 50 μm spot on the titanium target using an electrostatic quadrupole quadruplet previously used for the charged particle microbe...

متن کامل

Beam Monitors of Nirs Fast Scanning System for Particle Therapy

At National Institute of Radiological Sciences (NIRS), more than 6500 patients have been successfully treated by carbon-ion beams since 1994. The successful results of treatments have led us to construct a new treatment facility equipped with three-dimensional pencil beam scanning irradiation system. The commissioning of NIRS fast scanning system installed into the new facility was started in S...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003