Distribution of Central Corneal Thickness and its Association with Ocular Parameters in a Large Central European Cohort: The Gutenberg Health Study
نویسندگان
چکیده
MAIN OBJECTIVE To evaluate the distribution of central corneal thickness (CCT) in a large German cohort and to analyse its relationship with intraocular pressure and further ocular factors. DESIGN Population-based, prospective, cohort study. METHODS The Gutenberg Health Study (GHS) cohort included 4,698 eligible enrollees of 5,000 subjects (age range 35-74 years) who participated in the survey from 2007 to 2008. All participants underwent an ophthalmological examination including slitlamp biomicroscopy, intraocular pressure measurement, central corneal thickness measurement, fundus examination, and were given a questionnaire regarding glaucoma history. Furthermore, all subjects underwent fundus photography and visual field testing using frequency doubling perimetry. RESULTS Mean CCT was 557.3 ± 34.3 µm (male) and 551.6±35.2 µm in female subjects (Mean CCT from right and left eyes). Younger male participants (35-44 years) presented slightly thicker CCT than those older. We noted a significant CCT difference of 4 µm between right and left eyes, but a high correlation between eyes (Wilcoxon test for related samples: p<0.0001). Univariable linear regression stratified by gender showed that IOP was correlated with CCT (p<0.0001). A 10 µm increase in CCT led to an increase in IOP between 0.35-0.38 mm Hg, depending on the eye and gender. Multivariable linear regression analysis revealed correlations between gender, spherical equivalent (right eyes), and CCT (p<.0001 and p=0.03, respectively). CONCLUSIONS We observed positive correlations between CCT and IOP and gender. CCT was not correlated with age, contact lens wear, positive family history for glaucoma, lens status, or iris colour.
منابع مشابه
بررسی ارتباط بین ضخامت مرکز قرنیه و میزان فشار داخل چشمی اندازه گیری شده با تونومتر گلدمن
To determine the effect of central corneal thickness (CCT) on measured intraocular pressure (IOP) and evaluating the relationship between them in each of the groups of patients including: Normal subjects, ocular hypertension patients and patients with primary open angle glucoma (POAG). Correlation between intraocular pressure (Measured by Goldman applanation tonometer) and central corneal thick...
متن کاملComprehensive evaluation of dehydration impact on ocular tissue during Ramadan fasting
Purpose: The present study aimed to review the effect of dehydration during Ramadan fasting on the health and ocular parameters leading to changes in eye function. Methods: Articles included in the study were taken from Pub Med, Ovid, Web of Science and Google Scholar up to 2014.Related articles were also obtained from scientific journals in fasting and eye. Results: Dehydration and nutrition c...
متن کاملThe Biometric Values of Affected and Fellow Eyes in Patients with Acute Attack of Primary Angle Closure
Background: It has been estimated that 67 million people worldwide are affected with a primary glaucoma and that one-third have primary angle closure glaucoma. We aimed to determine the biometric differences between the eyes of patients with acute attack of primary angle closure and their non-involved fellow eyes. Methods: Twenty eight patients with acute attack of primary angle closure were re...
متن کاملComparison of Central Corneal Thickness Measured through Pentacam, OCTCasia2, and Orbscan IIz in Normal Individuals
Purpose: To compare the central corneal thickness measured through Pentacam, OCTCasia2, and Orbscan IIz in normal individuals. Methods: In this cross sectional comparative study, the researcher investigated the eyes of 70 normal candidates (140 eyes) with the mean age of 31.42 ± 7.70, referring to Dr. Sedaghat eye clinic for refractive surgery. For each person, Central Corneal Thickness (CCT) w...
متن کاملA 3-decade Activity of the Central Eye Bank of Iran
Purpose: To report a 3-decade eye bank data and activity of the Central Eye Bank of Iran (CEBI). Methods: All the eye bank records in terms of procured eyes, utilized tissues, corneal transplants per capita, and indications for keratoplasty over the last 3 decades were analyzed. Results: During the last 27 years, 115 743 whole eyes were donated, among which 114 169 eyes were donated between 199...
متن کامل