Combined 20-gauge and 23-gauge pars plana vitrectomy for the management of posteriorly dislocated lens: a case series

نویسنده

  • Pipat Kongsap
چکیده

OBJECTIVE To present a new surgical approach for the management of posteriorly dislocated lens by using a combination of 20-gauge (20G) and 23-gauge (23G) pars plana vitrectomy. DESIGN An interventional case series METHODS This technique was performed on six patients (five men, one woman; mean age, 66.67 years; range, 66-72 years). Two 23G trans-conjunctival sclerotomy ports were created for infusion and illumination along with a 20G sclerotomy port for introducing the vitrectomy probe or fragmatome. RESULTS This procedure was successfully performed on six eyes. On postoperative day one, the media were clear and the retina could be seen by indirect ophthalmoscopy. Hyphema developed in one eye and resolved within a week. There were no observed cases of retinal tear, wound leakage, hypotony, or endophthalmitis. The post-operative follow-up period ranged from three to twelve months (mean, 8.1 months). By the final visit, two patients had achieved a visual acuity of 20/40 or better, three patients, 20/70, and one patient, 20/200. CONCLUSION The combination of 20G and 23G pars plana vitrectomy is an efficacious and safe procedure for management of posteriorly dislocated lens.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

23-gauge pars plana vitrectomy for management of posteriorly dislocated crystalline lens

PURPOSE Management of posteriorly dislocated crystalline lens has traditionally been performed with a standard 20-gauge vitrectomy system. This study demonstrates the use of a 23-gauge vitrectomy system for removal of retained lens fragments secondary to spontaneous dislocation or complicated cataract extraction. METHODS A retrospective, noncomparative, interventional consecutive case series ...

متن کامل

Outcome of 23-gauge pars plana vitrectomy for pediatric vitreoretinal conditions.

PURPOSE To evaluate the feasibility and short-term outcome of 23-gauge vitrectomy in children for various vitreoretinal conditions. METHODS A retrospective chart review was conducted of consecutive children younger than 14 years who underwent 23-gauge transconjunctival sutureless vitrectomy for various vitreoretinal conditions from January 2008 to December 2011 at a tertiary care center. RE...

متن کامل

SUTURELESS CLEAR CORNEAL ULTRASONIC FRAGMENTATION FOR RETAINED LENS FRAGMENTS: A Pilot Study.

PURPOSE To describe the safety and efficacy of removing posteriorly dislocated lens fragments with the use of intravitreal ultrasonic fragmentation through a limbal, clear cornea self-sealing incision. METHODS Patients presenting with posteriorly luxated nuclei were enrolled in this prospective case series. Preoperative examination included evaluation of the corneal endothelium by means of sp...

متن کامل

Sutureless 25-Gauge Pars Plana Vitrectomy Combined with Retropupillary Fixation of an Iris-Claw Intraocular Lens

BACKGROUND The surgical case of a dropped intraocular lens inside the vitreous cavity constitutes a real challenge for the operating surgeon. Herein, we describe a case series where an alternative optical rehabilitation technique for late intraocular lens-bag complex dislocation has been used. METHODS A modern vitrectomy device was used to remove the capsule with the dropped intraocular lens ...

متن کامل

Comparison of retinal breaks observed during 23 gauge transconjunctival vitrectomy versus conventional 20 gauge surgery for proliferative diabetic retinopathy

BACKGROUND To assess the rate and type of retinal break formation in patients undergoing 23 gauge transconjunctival vitrectomy surgery for complications of proliferative diabetic retinopathy compared with 20 gauge vitrectomy surgery. METHODS Retrospective case notes review of two consecutive series of patients who had primary pars plana vitrectomy for complications of proliferative diabetic r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2010