Optimizing two-photon multiple fluorophore imaging of the human trabecular meshwork
نویسندگان
چکیده
PURPOSE Advances in two-photon (2P) deep tissue imaging provide powerful options for simultaneously viewing multiple fluorophores within tissues. We determined imaging parameters for optimally visualizing three fluorophores in the human trabecular meshwork (TM) to simultaneously detect broad-spectrum autofluorescence and multiple fluorophores through a limited number of emission filters. METHODS 2P imaging of viable human postmortem TM was conducted to detect Hoechst 33342-labeled nuclei, Alexa-568-conjugated phalloidin labeling of filamentous actin, and autofluorescence of the structural extracellular matrix (ECM). Emission detection through green (500-550 nm), near-red (565-605 nm), and far-red (590-680 nm) filters following 2P excitation at 750, 800, 850, and 900 nm was analyzed. Region-of-interest (ROI) image analysis provided fluorescence intensity values for each fluorophore. RESULTS Red-channel Alexa 568 fluorescence was of highest intensity with 2P 750 nm and 800 nm excitation. Alexa 568 was imperceptible with 900 nm excitation. With excitation at 750 nm and 800 nm, Hoechst 33,342 intensity swamped autofluorescence in the green channel, and marked bleed-through into red channels was seen. 850 nm excitation yielded balanced Hoechst 33342 and autofluorescence intensities, minimized their bleed-through into the far-red channel, and produced reasonable Alexa 568 intensities in the far-red channel. CONCLUSIONS 2P excitation at 850 nm and long-wavelength emission detection in the far-red channel allowed simultaneous visualization of the specific mix of endogenous and exogenous fluorophores with reasonably balanced intensities while minimizing bleed-through when imaging the human TM.
منابع مشابه
Two-photon imaging of the trabecular meshwork
PURPOSE To image the trabecular meshwork (TM) in its native unfixed state using a non-invasive, non-destructive technique. METHODS Two-photon microscopy (2PM), including two-photon excitation fluorescence (2PEF) and second harmonic generation (SHG), was used to image flat-mounted trabecular meshwork samples from human cadaver eyes. Multiple images were analyzed along the tissue axis (z-axis) ...
متن کاملLabel-free imaging of trabecular meshwork cells using Coherent Anti-Stokes Raman Scattering (CARS) microscopy
PURPOSE To image the human trabecular meshwork (TM) using a non-invasive, non-destructive technique without the application of exogenous label. METHODS Flat-mounted TM samples from a human cadaver eye were imaged using two nonlinear optical techniques: coherent anti-Stokes Raman scattering (CARS) and two-photon autofluorescence (TPAF). In TPAF, two optical photons are simultaneously absorbed ...
متن کاملTrans-scleral imaging of the human trabecular meshwork by two-photon microscopy
PURPOSE To image the native (unfixed) human trabecular meshwork (TM) through the overlying sclera using a non-invasive, non-destructive technique. METHODS Two-photon microscopic (2PM) methods, including two-photon autofluorescence (2PAF) and second harmonic generation (SHG), were used to image through the sclera of a human cadaver eye into the TM region. Multiple images were analyzed along th...
متن کاملRevisiting Ciliary Muscle Tendons and Their Connections With the Trabecular Meshwork by Two Photon Excitation Microscopic Imaging.
PURPOSE To elucidate the anatomy of the trabecular meshwork (TM) and its connection to ciliary muscle (CM) tendons with two photon excitation microscopic (TPEM) imaging. METHODS The human aqueous outflow pathway was imaged in an unfixed and nonembeded state by using an inverted TPEM. Laser (Ti:Sapphire) was tuned at 850 nm for emission. Backscatter signals of second harmonic generation (SHG) ...
متن کاملImaging the effects of prostaglandin analogues on cultured trabecular meshwork cells by coherent anti-stokes Raman scattering.
PURPOSE The aim of this study was to nondestructively monitor morphological changes to the lipid membranes of primary cultures of living human trabecular meshwork cells (hTMC) without the application of exogenous label. METHODS Live hTMC were imaged using two nonlinear optical techniques: coherent anti-Stokes Raman scattering (CARS) and two-photon autofluorescence (TPAF). The hTMC were treate...
متن کامل