Preformed vs intraoperative bending of titanium mesh for orbital reconstruction.

نویسندگان

  • E Bradley Strong
  • Scott C Fuller
  • David F Wiley
  • Janina Zumbansen
  • M D Wilson
  • Marc C Metzger
چکیده

OBJECTIVE The most accurate orbital reconstructions result from an anatomic repair of the premorbid orbital architecture. Many different techniques and materials have been used; unfortunately, there is currently no optimal method. This study compares the use of preformed vs intraoperative bending of titanium mesh for orbital reconstruction in 2-wall orbital fractures. STUDY DESIGN Cadaver-based study. SETTING University hospital. SUBJECTS AND METHODS Preinjury computed tomography scans were obtained in 15 cadaveric heads (30 orbits). Stereolithographic (STL) models were fabricated for 5 of the specimens (10 orbits). Two wall fractures (lamina papyracea and floor) were then generated in all orbits. Surgical reconstruction was performed in all orbits using 1 of 3 techniques (10 orbits each): (1) patient-specific implant molded from the preinjury STL model, (2) titanium mesh sheet bent freehand, and (3) preformed titanium mesh. Each technique was evaluated for orbital volume correction, contour accuracy, ease of use, and cost. RESULTS No difference in volume restoration was found between the 3 techniques. Patient-specific implants had the greatest contour accuracy, poor ease of use, and highest cost. Freehand bending implants had the poorest contour accuracy, acceptable ease of use, and lowest cost. Preformed mesh implants had intermediate contour accuracy, excellent ease of use, and low cost. CONCLUSION All 3 techniques provide equivalent orbital volume correction. However, preformed mesh implants have many advantages based on contour accuracy, ease of use, and relative cost.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative Study of Enophthalmos Treatment with Titanium Mesh Combined with Absorbable Implant vs. Costochondral Graft for Large Orbital Defects in Floor Fractures

Introduction: Several treatment options are available for the optimal treatment for orbital fractures, depending on aesthetic and functional results after orbital wall reconstruction. The objective of this study is to compare the effect and safety of large orbital fl oor fractures with titanium mesh combined with poly-L-lactic acid/polyglycolic acid copolymer implants (Lactosorb®) vs. autologou...

متن کامل

A Wrapping Method for Inserting Titanium Micro-Mesh Implants in the Reconstruction of Blowout Fractures.

Titanium micro-mesh implants are widely used in orbital wall reconstructions because they have several advantageous characteristics. However, the rough and irregular marginal spurs of the cut edges of the titanium mesh sheet impede the efficacious and minimally traumatic insertion of the implant, because these spurs may catch or hook the orbital soft tissue, skin, or conjunctiva during the inse...

متن کامل

Orbital Floor Reconstruction with Titanium Mesh;

.. Objective: To determine the outcome of orbital floor reconstruction with titanium mesh in terms of diplopia, enophthalmos, dystopia and infection etc. Study design: Descriptive case series. Place & duration of study: Department of Oral & Maxillofacial Surgery, Punjab Medical College / Allied Hospital Faisalabad. One and Half year from 01-10-12 to 31-03-14. Material and Method: Twenty two pat...

متن کامل

Orbital reconstruction: prefabricated implants, data transfer, and revision surgery.

External impact to the orbit may cause a blowout or zygomatico-maxillary fractures. Diagnosis and treatment of orbital wall fractures are based on both physical examination and computed tomography scan of the orbit. Injuries of the orbit often require a reconstruction of its orbital walls. Using computer-assisted techniques, anatomically preformed orbital implants, and intraoperative imaging of...

متن کامل

Patient specific implants (PSI) in reconstruction of orbital floor and wall fractures.

Fractures of the orbital wall and floor can be challenging due to the demanding three-dimensional anatomy and limited intraoperative overview. Misfitting implants and inaccurate surgical technique may lead to visual disturbance and unaesthetic results. A new approach using individually manufactured titanium implants (KLS Martin, Group, Germany) for daily routine is presented in the current pape...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery

دوره 149 1  شماره 

صفحات  -

تاریخ انتشار 2013