Liver fibrosis and Gd-EOB-DTPA-enhanced MRI: A histopathologic correlation

نویسندگان

  • Niklas Verloh
  • Kirsten Utpatel
  • Michael Haimerl
  • Florian Zeman
  • Claudia Fellner
  • Stefan Fichtner-Feigl
  • Andreas Teufel
  • Christian Stroszczynski
  • Matthias Evert
  • Philipp Wiggermann
چکیده

Gadolinium ethoxybenzyl-diethylenetriaminepentaacetic acid (Gd-EOB-DTPA) is a hepatocyte-specific MRI contrast agent. Because the hepatic uptake of Gd-EOB-DTPA depends on the integrity of the hepatocyte mass, this uptake can be quantified to assess liver function. We report the relationship between the extent of Gd-EOB-DTPA uptake and the degree of liver fibrosis. T1-weighted volume-interpolated breath-hold examination (VIBE) sequences with fat suppression were acquired before and 20 minutes after contrast injection. Strong correlations of the uptake characteristics of Gd-EOB-DTPA with the relative enhancement (RE) of the liver parenchyma and the grade of fibrosis/cirrhosis, classified using the Ishak scoring system, were observed. The subdivisions between the grades of liver fibrosis based on RE were highly significant for all combinations, and a ROC revealed sensitivities ≥82% and specificities ≥87% for all combinations. MR imaging is a satisfactorily sensitive method for the assessment of liver fibrosis/cirrhosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the efficacy of Gd-EOB-DTPA-enhanced magnetic resonance imaging and magnetic resonance elastography in the detection and staging of hepatic fibrosis

The present study compared the efficacy of gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) and magnetic resonance elastography (MRE) in the estimation of hepatic fibrosis stages with histopathologic correlation.This retrospective study included 104 patients (87 men and 17 women; mean age, 60.6 ± 10.6 years) with chronic liver d...

متن کامل

MR Prediction of Liver Function and Pathology Using Gd-EOB-DTPA: Effect of Liver Volume Consideration

PURPOSE To evaluate whether the diagnostic performance of Gd-EOB-DTPA-enhanced MRI in evaluating liver function and pathology is improved by considering liver volume (LV). METHODS This retrospective study included 104 patients who underwent Gd-EOB-DTPA-enhanced MRI before liver surgery. For each patient, using the precontrast and hepatobiliary phase images, we calculated the increase rate of ...

متن کامل

Gd-EOB-DTPA-enhanced MRI for evaluation of liver function: Comparison between signal-intensity-based indices and T1 relaxometry

Gadolinium ethoxybenzyl-diethylenetriaminepentaacetic acid (Gd-EOB-DTPA) is a paramagnetic hepatobiliary magnetic resonance (MR) contrast agent. Due to its OATP1B1/B3-dependent hepatocyte-specific uptake and paramagnetic properties increasing evidence has emerged to suggest that Gd-EOB-DTPA-enhanced MRI can be potentially used for evaluation of liver function. In this paper we compare the diagn...

متن کامل

Dynamic-contrast-enhanced magnetic resonance imaging of cirrhotic liver parenchyma: A comparison between gadolinium-diethylenetriamine pentaacetic acid and gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid.

BACKGROUND The newly developed magnetic-resonance-imaging (MRI) hepatocyte-specific contrast agent, gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid (Gd-EOB-DTPA), has different excretion pathways from the conventional MRI contrast agent, gadolinium-diethylenetriamine pentaacetic acid (Gd-DTPA). In this study, we compare the enhancement effect of the liver and renal parenchyma betwee...

متن کامل

MRI-based estimation of liver function: Gd-EOB-DTPA-enhanced T1 relaxometry of 3T vs. the MELD score

Gd-EOB-DTPA is a hepatocyte-specific MRI contrast agent. Due to its hepatocyte-specific uptake and paramagnetic properties, functioning areas of the liver exhibit shortening of the T1 relaxation time. We report the potential use of T1 relaxometry of the liver with Gd-EOB-DTPA-enhanced magnetic resonance imaging (MRI) for estimating the liver function as expressed by the MELD score. 3 T MRI rela...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2015