Determination of the nature and origin of the metallic foreign particles appearing on the iris after phacoemulsification.
نویسندگان
چکیده
PURPOSE To determine the nature and the origin of metallic foreign particles appearing on the iris after phacoemulsification surgery. SETTING P.D. Hinduja Hospital and Medical Research Centre, Mumbai, Maharashtra, India. DESIGN Case series. METHODS Metallic foreign particles were observed on the iris surface and the pupillary border on the first postoperative visit after phacoemulsification. One metallic particle, which was stuck to the iris surface, was removed intraoperatively and sent for metal analysis along with the phaco needle, the wrench used to tighten the phaco needle to the phaco handpiece, and the anterior chamber maintainer used during phacoemulsification. The composition of the elements was studied by scanning electron microscopy (SEM) to determine the origin of the metallic particle. RESULTS Foreign particles were seen in 11 eyes. On SEM, 3 elements (carbon, magnesium, and silicone) were common in the metal particle and 4 elements (carbon, magnesium, silicone, and titanium) on the wrench. The elements in the phaco needle (titanium) and anterior chamber maintainer (manganese, iron, and nickel) did not match those in the metal particle. CONCLUSION The metal contents of the metallic particle extracted from the eye matched some of the constituent metals of the wrench that was used to tighten the phaco needle on the handpiece just before surgery. FINANCIAL DISCLOSURE No author has a financial or proprietary interest in any material or method mentioned.
منابع مشابه
Appendicitis Caused by Metallic Foreign Body in the Appendix
Although uncommon, different kinds of foreign bodies, most of which metallic, have been reported to enter the appendix. The present report describes a case with a metallic foreign body-induced appendicitis, and makes suggestion in regards to the diagnosis and management of the problem. A metallic foreign body was accidentally observed in the right lower quadrant region in an abdominal X-ray tak...
متن کاملUnusual Presentation of Metallic Foreign Body Aspiration after Penetrating Neck Trauma
A 25 year-old Construction worker underwent neck laceration following penetrating neck trauma in a falling incident. The 3rd tracheal ring was injured which was initially repaired and the patient was discharged in good general condition. (Figure 1 shows the patient’s neck view after discharge from hospital).Two months later the patient was again admitted due to provocative coughing and a metal ...
متن کاملORE extraction and blending optimization model in poly- metallic open PIT mines by chance constrained one-sided goal programming
Determination a sequence of extracting ore is one of the most important problems in mine annual production scheduling. Production scheduling affects mining performance especially in a poly-metallic open pit mine with considering the imposed operational and physical constraints mandated by high levels of reliability in relation to the obtained actual results. One of the important operational con...
متن کاملگذار نیمرسانا به فلز در پلیاستیلن (trans-PA) (نقش سالیتونهای همبسته)
In this study the nature of transition to metallic regime in trans-polyacetylene (trans-PA) is investigated. Based on Su-Schrieffer-Heeger (SSH) model and the use of Continued - Fraction Representation (CFR) as well as Lanczos algorithm procedure, we studied the effects of some selected soliton distributions on the semiconductor-to-metal transition in trans-PA.We found that,this transition occ...
متن کاملA Case of an Asymptomatic Intralenticular Foreign Body
The purpose of this article is to report a case of an asymptomatic intralenticular metallic foreign body that was retained for 6 months. A 66-year-old male visited our ophthalmology department because of decreased visual acuity in his left eye 6 months after he suffered ocular trauma while mowing. He had not been treated because he did not experience any discomfort. His corrected visual acuity ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of cataract and refractive surgery
دوره 39 7 شماره
صفحات -
تاریخ انتشار 2013