Advances in Fourier-domain optical coherence tomography (Fd-OCT) permit visualization of three-dimensional morphology of in-vivo retinal structures in a way that promises to revolutionize clinical and experimental imaging of the retina. The relevance of these advances will be further increased by the recent introduction of several commercial FdOCT instruments that can be used in clinical practice. However, due to some inherent limitations of current Fd-OCT technology (e.g., lack of spectroscopic information, inability to measure fluorescent signals), it is important to coregister Fd-OCT data with images obtained by other clinical imaging modalities such as fundus cameras and fluorescence angiography to create a more complete interpretation and representation of structures imaged. The coregistration between different imaging platforms becomes even more important if small retinal changes are monitored for early detection and treatment. Despite advances in volume acquisition speed with FD-OCT, eye/head motion artifacts can be still seen on acquired data. Additionally high-sampling density, large field-of-view (FOV) Fd-OCT volumes may also be needed for comparison with conventional imaging. In standard Fd-OCT systems, higher sampling density and larger imaging FOV (with constant sampling densities) lead to longer acquisition time which further increases eye/head motion artifacts. To overcome those problems, we tested 3D stitching of multiple, smaller retinal volumes which can be acquired in a less time (reduction of motion artifacts) and/or when stitched create a larger FOV representation of the retina. Custom visualization software that makes possible manual co-registration and simultaneous visualization of volumetric Fd-OCT data sets is described. Volumetric visualizations of healthy retinas with corresponding fundus pictures are presented followed by examples of retinal volumes of high sampling density that are created from multiple “standard” Fd-OCT volumes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cellular resolution volumetric in vivo retinal imaging with adaptive optics-optical coherence tomography.

Ultrahigh-resolution adaptive optics-optical coherence tomography (UHR-AO-OCT) instrumentation allowing monochromatic and chromatic aberration correction was used for volumetric in vivo retinal imaging of various retinal structures including the macula and optic nerve head (ONH). Novel visualization methods that simplify AO-OCT data viewing are presented, and include co-registration of AO-OCT v...

متن کامل

Automated non-rigid registration and mosaicing for robust imaging of distinct retinal capillary beds using speckle variance optical coherence tomography

Variance processing methods in Fourier domain optical coherence tomography (FD-OCT) have enabled depth-resolved visualization of the capillary beds in the retina due to the development of imaging systems capable of acquiring A-scan data in the 100 kHz regime. However, acquisition of volumetric variance data sets still requires several seconds of acquisition time, even with high speed systems. M...

متن کامل

Segmentation guided registration of wide field-of-view retinal optical coherence tomography volumes.

Patient motion artifacts are often visible in densely sampled or large wide field-of-view (FOV) retinal optical coherence tomography (OCT) volumes. A popular strategy for reducing motion artifacts is to capture two orthogonally oriented volumetric scans. However, due to larger volume sizes, longer acquisition times, and corresponding larger motion artifacts, the registration of wide FOV scans r...

متن کامل

In vivo volumetric imaging of human retinal circulation with phase-variance optical coherence tomography

We present in vivo volumetric images of human retinal micro-circulation using Fourier-domain optical coherence tomography (Fd-OCT) with the phase-variance based motion contrast method. Currently fundus fluorescein angiography (FA) is the standard technique in clinical settings for visualizing blood circulation of the retina. High contrast imaging of retinal vasculature is achieved by injection ...

متن کامل

Correction of motion artifacts and scanning beam distortions in 3D ophthalmic optical coherence tomography imaging

The ability to obtain true three-dimensional (3D) morphology of the retinal structures is essential for future clinical and experimental studies. It becomes especially critical if the measurements acquired with different instruments need to be compared, or precise volumetric data are needed for monitoring and treatment of retinal disease. On the other hand, it is well understood that optical co...