Effects of fatty acyl chain length, double-bond number and matrix on phosphatidylcholine responses in matrix-assisted laser desorption/ionization on an Orbitrap mass spectrometer.

نویسندگان

  • Vitaliy Chagovets
  • Miroslav Lísa
  • Michal Holčapek
چکیده

RATIONALE Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is used for the fast qualitative and quantitative analysis of phosphatidylcholines (PC). Fatty acyl chain lengths and the number of double bonds (DB) affect relative responses of PC; hence the determination of correction factors of individual PC is important for the accurate quantitation. The signal intensity in MALDI-MS strongly depends on the matrix; therefore, the following matrices typically used in lipidomics are studied in the present work: 2,5-dihydroxybenzoic acid (DHB), 1,5-diaminonaphthalene (DAN) and 9-aminoacridine (9AA). METHODS Series of PC with various fatty acyl chain lengths are synthesized for this study. PC concentrations over two orders of magnitude are studied with MALDI-MS. These experiments provide sets of calibration curves for each of the synthesized PC and the further analysis of parameters of calibration curves is performed. RESULTS Correction factors for PC decrease with increasing fatty acyl chain length for all matrices. These dependences are steeper for unsaturated PC than for saturated ones. MALDI matrices also have a significant effect on this dependence. The weakest dependence on fatty acyl chain length is found for saturated PC in 9AA. In the case of the other matrices, the effect of fatty acyl chain length on the response is essential for both saturated and unsaturated PC. Calibration curves and parameters of calibration curves for both saturated and monounsaturated PC are fitted by a linear function with regression coefficients decreasing in the order 9AA > DAN > DHB. CONCLUSIONS Differences in relative responses for PC in MALDI-MS measurements must be taken into account for accurate quantitation. Parameters of calibration curves can be used for the determination of PC concentrations using a single internal standard (IS). This method gives good results for the 9AA matrix, but the reproducibility of measurements for the DHB and DAN matrices is lower and the method can be used for a rough estimation only. These matrices are less convenient for the quantitation of PC.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlative mass spectrometry imaging, applying time‐of‐flight secondary ion mass spectrometry and atmospheric pressure matrix‐assisted laser desorption/ionization to a single tissue section

RATIONALE Mass spectrometry imaging (MSI) is a powerful tool for mapping the surface of a sample. Time-of-flight secondary ion mass spectrometry (TOF-SIMS) and atmospheric pressure matrix-assisted laser desorption/ionization (AP-MALDI) offer complementary capabilities. Here, we present a workflow to apply both techniques to a single tissue section and combine the resulting data for the example ...

متن کامل

Structural characterization of triacylglycerols as lithiated adducts by electrospray ionization mass spectrometry using low-energy collisionally activated dissociation on a triple stage

A.) Neutral Acylglycerols and Free Fatty Acids by ESI/MS/MS ....................................... 7 A.1.) Structural characterization of triacylglycerols as lithiated adducts by electrospray ionization mass spectrometry using low-energy collisionally activated dissociation on a triple stage quadrupole instrument. ...................................................................................

متن کامل

Charge-remote fragmentation of lithiated fatty acids on a TOF-TOF instrument using matrix-ionization.

In numerous studies charge remote fragmentation (CRF) has been shown to be a powerful technique for determination of primary structure by allowing location of double bonds, various functional groups, and branching in a variety of compound types directly by mass spectrometry. Instrumentation and ionization methods traditionally used for CRF, however, are becoming rare, in large part because ESI ...

متن کامل

Enzymatic and genetic characterization of firefly luciferase and Drosophila CG6178 as a fatty acyl-CoA synthetase.

Recently we found that firefly luciferase is a bifunctional enzyme, catalyzing not only the luminescence reaction but also long-chain fatty acyl-CoA synthesis. Further, the gene product of CG6178 (CG6178), an ortholog of firefly luciferase in Drosophila melanogaster, was found to be a long-chain fatty acyl-CoA synthetase and dose not function as a luciferase. We investigated the substrate speci...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Rapid communications in mass spectrometry : RCM

دوره 29 24  شماره 

صفحات  -

تاریخ انتشار 2015