Colorimetric measurement of uric acid.

نویسنده

  • R M ARCHIBALD
چکیده

HEN ASKED IN 1942 to find a method for the determination of plasma or serum uric acid suitable for inclusion in the War Department’s Technical Manual 8-227, Method,s for Laboratory Technicians, the author believed that the procedure of Kern and Stransky (1) filled the requirements admirably. In this modification, toxic and heat-labile sodium cyanide solution wa replaced by the effective but nontoxic and relatively stable glycerine-silicate reagent. However, when the method of Kern and Stransky was used exactly as directed, colored solutions quickly became turbid when the glycerine-silicate used was prepared from either a diluted water-glass preparation or from a solid silicate. Furthermore, use of any one of the available preparations of glycerine resulted in a reagent mixture which permitted development of turbidity. As Kern and Stransky made no mention of such turbidity, it seems likely that the glycerine preparations available to them contained some impurity which inhibited precipitation from the glycerine-silicate mixture. In any case, addition of Liquoid La Roche, a Swiss preparation of sodium polyanethol sulfonate, consistently prevented development of turbidity in the colored solutions. No adequate substitute for this sulfonate was found. The first few batches of Liquoid prepared in this country were also unable to prevent development of turbidity. However, batches of Liquoid marketed by Hoffman-La Roche, Inc., during the past ten years appear to be completely satisfactory. To decrease the number of reagents required for conduct of this procedure, the protein precipitant (uranyl acetate) employed by Kern and Stransky was replaced by the reagent used for the development of color. Thus, the phosphotungstic acid reagent serves not only for the development of color, but also for the precipitation of blood proteins.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optical nonlinearity in measurement of urea and uric acid in blood

The Z-scan technique is a simple and effective tool for determining nonlinear optical properties of materials. This technique is utilized in measurement of urea and uric acid in blood. The nonlinear refractive index of urea and uric acid are found to vary linearly with concentration. Hence by calculating the nonlinear refractive index it is possible to measure their concentration in the sample....

متن کامل

Measurement of uric acid in biologic fluids using an ion-exchange separation.

HE MAJOR METHODS CURRENTLY IN USE for the determination of uric cid in biologic fluids are the colorimetric (1-3), the titrimetric (4), and he enzymatic (5-7). All of these methods are performed directly on the luid to be measured and are therefore subject to the effects of interfering ubstances present in these fluids. Since the colorimetric and titrimetric echnics depend on the reducing abili...

متن کامل

Simultaneous Voltammetric Measurement of Ascorbic Acid, Epinephrine, Uric Acid and Tyrosine at a Glassy Carbon Electrode Modified with Nanozeolite-Multiwall Carbon Nanotube

In this study, incorporation of iron ion-doped natrolite nanozeolite, multi-wall carbon nanotubes into chitosan-coated glassy carbon electrode for the simultaneous determination of ascorbic acid, epinephrine, uric acid and tyrosine is studied. The results show that the combination of multi-wall carbon nanotubes and iron ion-doped natrolite zeolite causes a dramatic enhancement in the sensitivit...

متن کامل

Calorimetric enzymic measurement of uric acid in serum.

Uric acid in serum was determined calorimetrically with a batch type microcalorimeter, by measuring the heat evolved during a coupled uricase/catalase enzymic reaction in tris(hydroxymethyl)aminomethane HCl buffer (pH 9.0 at 30 degrees C). Heat evolution and concentration are linearly related through the physiological range of serum uric acid concentrations and the method is free of interferenc...

متن کامل

Comparison of a Colorimetric (automated) with an Enzymatic (manual) Uric Acid Procedure.

‘J’HE MOST COMMONLY USED METHODS for the estimation of uric acid are those colorimetric procedures utilizing the reduction of phosphotungstic acid (1-7). Since these procedures are not specific for uric acid, an enzymatic procedure utilizing uricase, which oxidizes uric acid to allantoin, has been employed by a number of investigators (8-12). The enzymatic method, dependent upon the absorption ...

متن کامل

The automated determination of serum uric acid.

An automated procedure is presented for the enzymatic determination of serum uric acid on both the AutoAnalyzer and the Robot Chemist. The procedure measures as the neocuproine complex, the difference in the amount of Cu+ formed by reaction of a Cu++ aIkanoIamine buffered solution with serum uric acid under precisely controlled conditions before and after uricase treatment of the serum. The dif...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 3 2  شماره 

صفحات  -

تاریخ انتشار 1957