Improving Tube Design of a Problematic Heat Exchanger for Enhanced Safety at Minimal Costs

نویسندگان

  • In-Bok Lee
  • Seunghee Park
چکیده

As part of a preliminary hazard analysis for a new phenol plant, the results of a hazard and operability study (HAZOP) conducted in the initial stages of the project design were re-evaluated due mechanical failure detected during the test operation. Out of the possible mechanical defects for the crude phenol column (CPC), the fact that the lowest risk grade was given to the column without consideration for any safety devices, was recognized as the cause of failure. After examining the design specifications of the safety valves of CPC, it was confirmed that the tube rupture case of the overhead condenser was also not taken into consideration. With this case included in HAZOP, the size of the safety valve had to be increased from 6Q8 to 8T10. In summary, when taking into consideration the economic impact on modification and re-purchase of the safety valve and the redesign of the piping system might have, it was determined that completely removing any possibility for the tube rupture case by mechanically reinforcing the overhead condenser would be the most economic decision. Therefore, the overhead condenser was mechanically reinforced in areas determined to require strengthening according to the results of the vibration analysis, and by adding these results to the safety device factors of the mechanical defects of CPC, the lowest safety risk grade could have been maintained.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimal Design of Shell-and-Tube Heat Exchanger Based on Particle Swarm Optimization Technique

The paper studies optimization of shell-and-tube heat exchangers using the particle swarm optimization technique. A total cost function is formulated based on initial and annual operating costs of the heat exchangers. Six variables – shell inside diameter, tube diameter, baffle spacing, baffle cut, number of tube passes and tube layouts (triangular or square) – are considered as the design para...

متن کامل

How to Design a Cryogenic Joule-Thomson Cooling System: Case Study of Small Hydrogen Liquefier

Heat exchangers are the critical components of refrigeration and liquefaction processes. Selection of appropriate operational conditions for cryogenic recuperative heat exchanger and expansion valve operating in Joule-Thomson cooling system results in improving the performance and efficiency. In the current study, a straightforward procedure is introduced to design an efficient Joule-Thomson co...

متن کامل

Thermal Design Considerations and Performance Evaluation of Cryogenic Tube in Tube Heat Exchangers

Heat exchangers are the most important equipment in refrigeration processes. Design and modeling of heat exchangers operating at low temperatures are different from other regular heat exchangers. This study includes two sections. In the first section, design and modeling considerations needed for evaluating the real thermal behavior of heat exchangers at low temperatures were discussed. The...

متن کامل

Investigation of Heat Transfer Coefficient Enhancement for CuO/TiO2 Nanocomposite in a Tube Heat Exchanger

In order to improve the efficiency and rate of heat transfer in heat exchangers, various techniques such as increasing the heat transfer coefficient are proposed. This study is devoted to the investigation of heat transfer coefficient variations due to the addition of CuO, TiO2 and CuO/TiO2 nanoparticles into a shell and tube heat exchanger. CuO/TiO2 nanocomposite was synthesized using mechanic...

متن کامل

Effect of Wire Pitch on Capacity of Single Staggered Wire and Tube Heat Exchanger Using Computational Fluid Dynamic Simulation

Single staggered is a design development of normal wire and tube heat exchanger that wires are welded with staggered configuration on two sides. Capacity of wire and tube heat exchanger is the ability of the heat exchanger to release heat. The objective of this study is to analyse the effect of wire pitch (pw) on capacity of single staggered wire and tube heat exchanger. The research...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017