Respiration activity monitoring system for any individual well of a 48-well microtiter plate

نویسندگان

  • David Flitsch
  • Sebastian Krabbe
  • Tobias Ladner
  • Mario Beckers
  • Jana Schilling
  • Stefan Mahr
  • Uwe Conrath
  • Werner K. Schomburg
  • Jochen Büchs
چکیده

BACKGROUND Small-scale micro-bioreactors have become the cultivation vessel of choice during the first steps of bioprocess development. They combine high cultivation throughput with enhanced cost efficiency per cultivation. To gain the most possible information in the early phases of process development, online monitoring of important process parameters is highly advantageous. One of these important process parameters is the oxygen transfer rate (OTR). Measurement of the OTR, however, is only available for small-scale fermentations in shake flasks via the established RAMOS technology until now. A microtiter plate-based (MTP) μRAMOS device would enable significantly increased cultivation throughput and reduced resource consumption. Still, the requirements of miniaturization for valve and sensor solutions have prevented this transfer so far. This study reports the successful transfer of the established RAMOS technology from shake flasks to 48-well microtiter plates. The introduced μRAMOS device was validated by means of one bacterial, one plant cell suspension culture and two yeast cultures. RESULTS A technical solution for the required miniaturized valve and sensor implementation for an MTP-based μRAMOS device is presented. A microfluidic cover contains in total 96 pneumatic valves and 48 optical fibers, providing two valves and one optical fiber for each well. To reduce costs, an optical multiplexer for eight oxygen measuring instruments and 48 optical fibers is introduced. This configuration still provides a reasonable number of measurements per time and well. The well-to-well deviation is investigated by 48 identical Escherichia coli cultivations showing standard deviations comparable to those of the shake flask RAMOS system. The yeast Hansenula polymorpha and parsley suspension culture were also investigated. CONCLUSIONS The introduced MTP-based μRAMOS device enables a sound and well resolved OTR monitoring for fast- and slow-growing organisms. It offers a quality similar to standard RAMOS in OTR determination combined with an easier handling. The experimental throughput is increased 6-fold and the media consumption per cultivation is decreased roughly 12.5-fold compared to the established eight shake flask RAMOS device.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Parallel use of shake flask and microtiter plate online measuring devices (RAMOS and BioLector) reduces the number of experiments in laboratory-scale stirred tank bioreactors

BACKGROUND Conventional experiments in small scale are often performed in a 'Black Box' fashion, analyzing only the product concentration in the final sample. Online monitoring of relevant process characteristics and parameters such as substrate limitation, product inhibition and oxygen supply is lacking. Therefore, fully equipped laboratory-scale stirred tank bioreactors are hitherto required ...

متن کامل

Re: Europium nanoparticles and time-resolved fluorescence for ultrasensitive detection of prostate-specific antigen.

BACKGROUND Nanoparticle-based detection technologies have the potential to improve detection sensitivity in miniature as well as in conventional biochemical assays. We introduce a detection technology that relies on the use of europium(III) nanoparticles and time-resolved fluorometry to improve the detection limit of biochemical assays and to visualize individual molecules in a microtiter plate...

متن کامل

Light-induced gene expression with photocaged IPTG for induction profiling in a high-throughput screening system.

BACKGROUND Inducible expression systems are frequently used for the production of heterologous proteins. Achieving maximum product concentrations requires induction profiling, namely the optimization of induction time and inducer concentration. However, the respective experiments can be very laborious and time-consuming. In this work, a new approach for induction profiling is presented where in...

متن کامل

Semiautomated microtiter plate assay for monitoring peptidylprolyl cis/trans isomerase activity in normal and pathological human sera.

An UV/VIS spectrophotometric assay technique was developed that was able to routinely monitor peptidylprolyl cis/trans isomerase (PPIase) activity of biological fluids in 96-well microtiter plates. The assay, based on monitoring the cis-to-trans isomerization of succinyl-Phe-cisPro-Phe-4-nitroanilide as substrate in a chymotrypsin-coupled reaction, yields a throughput of 96 samples per 30 min. ...

متن کامل

Fed-batch like cultivation in a micro-bioreactor: screening conditions relevant for Escherichia coli based production processes

OBJECTIVES Recombinant protein production processes in Escherichia coli are usually operated in fed-batch mode; therefore, the elaboration of a fed-batch cultivation protocol in microtiter plates that allows for screening under production like conditions is particularly appealing. RESULTS A highly reproducible fed-batch like microtiter plate cultivation protocol for E. coli in a micro-bioreac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2016