Increased risks of endotracheal tube cuff colonization after prolonged intubation.

نویسندگان

  • Wen-Hui Tsai
  • Hui-Chi Hsu
  • Chung-Hung Shih
چکیده

Mechanical ventilation using endotracheal tube (ETT) intubation is crucial in saving life but may also cause ventilator-associated pneumonia resulting in morbidity and mortality. The purpose of this study was to examine the effects of intubation duration on pathogen colonization rates of ETT cuff region, and its association with the subsequent re-intubation and tracheostomy. We enrolled 92 patients who were successfully weaned from ventilator and were extubated within 20 days of intubation duration. Patients were divided into Group I and II based on intubation for 1-9 days and 10-20 days, respectively. Pathogen colonization over ETT cuff region and extra-cuff region (including sputum and ETT aspirates) were assessed. As compared to Group I patients, Group II patients had a significant higher pathogen colonization rate (100% vs. 69.2%; P < 0.001) in the ETT cuff samples, but not in the extra-cuff samples (92.6% vs. 84.8%; P = 0.442). Further studies demonstrated that there was no difference between Group I and II patients in the percentages of patients with the same pathogen over both the cuff and extra-cuff samples (35.5% vs. 30.8%; P = 0.925), suggesting that the increased pathogen colonization rate over the ETT cuff region was least likely from the extra-cuff region. In addition, the results showed that longer intubation was also associated with increased tracheostomy rate from 9.3% to 28.9% for Group I and Group II respectively (P = 0.025). We conclude that longer intubation has a higher pathogen colonization rate over the ETT cuff region in patients receiving mechanical ventilation support; longer intubation also increases the trend of receiving re-intubation and tracheostomy. Our findings indicate that it is crucial to remove ETT as soon as possible and perform pathogen culture over the ETT cuff regions immediately after extubation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of tracheal tube cuff inflation pressure among anesthesia team with different gradual level

Background & Objectives: Tracheal intubation is frequently performed in operating room. Over inflation of the endotracheal tube cuff is a risk factor for tracheal ischemia and subsequent complications. On the other hand inadequate cuff pressure increases the risk of aspiration of gastric contents. In this study, the endotracheal tube cuff pressure filled by the anesthesia team has been compared...

متن کامل

Study of endotracheal tube cuff pressure and time of measurement among intensive care units patients

Introduction: The pressure in the endotracheal tube cuff must be kept within an optimal range, to make sure tracheal capillaries circulation still stable during positive ventilation. This is essential to avoid oral and gastric stuffing aspiration Objective: The objective of this study was to assess the endotracheal tube cuff pressure and time intervals measurements among intensive care units...

متن کامل

Tracheal damage after endotracheal intubation: comparison of two types of endotracheal tubes.

Twenty-eight patients who required endotracheal intubation for open-heart surgery were randomly allocated to one of two types of endotracheal tube. The tracheal mucosa was examined with a fibreoptic bronchoscope at the time of extubation, usually 24 hours after operation. The degree of oedema, inflammation, and ulceration was scored by the bronchoscopist, who also photographed the whole length ...

متن کامل

Maintaining endotracheal tube cuff pressure at 20 mm Hg to prevent dysphagia after anterior cervical spine surgery; protocol of a double-blind randomised controlled trial

BACKGROUND In anterior cervical spine surgery a retractor is obligatory to approach the spine. Previous studies showed an increase of endotracheal tube cuff pressure after placement of a retractor. It is known that high endotracheal tube cuff pressure increases the incidence of postoperative dysphagia, hoarseness, and sore throat. However, until now no evidence supports the fact whether adjusti...

متن کامل

Repeated Tracheostomy Tube Cuff Rupture Due to Tracheobronchopathia Osteochondroplastica: A Case Report

Introduction: Tracheobronchopathia osteochondroplastica (TPO) is a rare benign disorder of the lower part of the trachea and the upper part of the main bronchi.   Case Report: A case of tracheobronchopathia osteochondroplastica (TPO) diagnosed at the time of intubation in an intensive care unit due to difficulty when advancing the endotracheal tube beyond the vocal cords, is reported. A problem...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Chinese journal of physiology

دوره 57 3  شماره 

صفحات  -

تاریخ انتشار 2014