Influence of boronization on operation with high-Z plasma facing components in Alcator C-Mod
نویسندگان
چکیده
We report the results of operation of Alcator C-Mod with all high-Z molybdenum Plasma Facing Component (PFC) surfaces. Without boron-coated PFCs energy confinement was poor (HITER,89 ~ 1) due to high core molybdenum (nMo/ne 0.1%) and radiation. After applying boron coatings, nMo/ne was reduced by a factor of 10-20 with HITER,89 approaching 2. Results of between-discharge boronization, localized at various major radii, point towards important molybdenum source regions being small, outside the divertor, and due to RFsheath-rectification. Boronization also has a significant effect on the plasma startup phase lowering Zeff, radiation, and lowering the runaway electron damage. The requirement of lowZ coatings over at least a fraction of the Mo PFCs in C-Mod for best performance together with the larger than expected D retention in Mo, give impetus for further high-Z PFC investigations to better predict the performance of uncoated tungsten surfaces in ITER and
منابع مشابه
RF Plasma Edge Interactions and Their Impact on ICRF Antenna Performance in Alcator C-Mod
In Alcator C-Mod, we have investigated the compatibility of high power ion cyclotron range of frequencies antenna with high performance plasmas and all high-Z plasma facing components, to provide operational information for future devices such as ITER. Boronization appears to be critical achieving low radiated power plasmas and is eroded rapidly such that the best performance is lost when the i...
متن کاملAlcator C-Mod Ion Cyclotron Antenna Performance
One of the keys to successful ion cyclotron range of frequency (ICRF) heating is antenna performance. In Alcator C-Mod, we have investigated the compatibility of high power ICRF antennas with high performance plasmas and all high-Z plasma facing components, to provide operational information for future devices such as ITER. Boronization appears to be critical to control plasma radiation but it ...
متن کاملAlcator C-Mod FY2005 Level-1 OFES Science Target Completion Report: “Measure Plasma Behavior with All-Metal Walls and Input Power Greater than 3.5 MW”
This report documents the results of experiments and analysis on the operations of Alcator C-Mod during the Fiscal Year 2005 campaign to study the effects of removing all boron-nitride protection limiters and cleaning all metal surfaces as thoroughly as possible to return the machine to conditions with all-metal plasma facing components. ICRF antenna performance, heating efficiency, disruption ...
متن کاملPFC / JA - 94 - 02 First Ohmic H - modes in Alcator C - MOD
Ohmic H-modes have been achieved in Alcator C-Mod with toroidal fields up to BT5.25 T and line averaged densities up to n e 1.4 x 1020 m-3 with less than 1 MW of input power. In ELM-free cases at lower toroidal field, the energy confinement increases by at least 60% and the particle confinement increases by more than a factor of two. The ELM-free H-modes appear to fit the threshold power scalin...
متن کاملTungsten Measurement on Alcator C-Mod and EBIT for Future Fusion Reactors
Tungsten will be an important element in nearly all future fusion reactors because of its presence in plasma facing components. This makes tungsten a good candidate for a diagnostic element for ion temperature and toroidal velocity measurement, and it makes understanding tungsten emissions important for tokamak power balance. The effect of tungsten on tokamak plasmas is investigated at the Alca...
متن کامل