Development of a 2.0 Tesla permanent magnetic circuit for NMR/MRI

نویسندگان

  • T. HAISHI
  • M. AOKI
  • E. SUGIYAMA
چکیده

We have developed the 2.0T permanent magnetic circuit for NMR/MRI (figure1). In the previous study, the maximum field strength of permanent magnets for MRI was 1.0T [1, 3]. With using NdFeB magnetic materials and a special magnetic circuit design, it has been achieved that the magnetic field strength of 2.03 Tesla, H center frequency of 86.3MHz, air gap of 60 mm, 10 ppm-homogeneous volume of 30 mm DSV (diameter spherical volume), outer size of 80 cm× 63 cm× 84 cm. NMR/MRI experiments were performed with using a compact NMR/MRI console [2] and RF solenoid coil. High resolution 3D MR microscopy images (100um res.) of a human finger in vivo were acquired in several minutes (figure 2). Three chemical-sift lines in Ethanol spectrum (figure 3, CH3OH2OH, 4 cc) were clearly measured with current shimming of higher orders. These result promises the stability and wide-use of the maintenance-free 2.0T permanent magnets. Introduction Figure 4 shows an example of permanent magnetic circuits which is used for usual medical MRI systems. Currently NdFeB materials have a maximum energy-product in magnetic materials. Almost of all 0.2T-0.4T whole body MRI system employ the typical magnetic circuit and NdFeB materials. This magnetic circuit is consisted of three major parts; yolks, magnetic-materials, and pole-pieces. The magnetic circuit has a advantage of its simple mechanical-structure, however the iron yolk cause a trouble of heavy weight more and more as increasing its air-gap or magnetic field-strength. On the other hand we had developed a 4.4T permanent magnetic circuit [4] (figure 5, 50 kg, ID: 6 mm, Halbach type) for a polarizing lens for an instrument of linear accelerators. Unfortunately the 4.4T magnet did not have enough field homogeneity for NMR/MRI at its 6 mm diameter. Figure 6 shows a magnetic circuit design modified from Halbach type especially for NMR/MRI applications. In the previous study [1, 3] a 1.0T magnetic circuit (44 MHz, 10 ppm@ 20 mmDSV, 60 mm gap, 200 kg) was developed. Materials and imaging experiment The 2.0T magnet with NdFeB shown in figure 1 (left), has achieved that the field strength of 2.03 T, H center frequency of 86.3MHz, air gap of 60 mm, 10 ppm-homogeneous volume of 30 mm DSV, outer size of 80 cm× 63 cm× 84 cm. The 2.0T magnet has double bores of vertical& horizontal crossing at the homogeneous volume and NMR/MRI samples are easily placed at the iso-center. The whole magnetic circuit is covered with thermal insulators, so that the resonance frequency changing caused by temperature drifts is reduced within 1kHz with using a PID control of heaters attached to the magnet. NMR/MRI experiments for the 2.0T magnet were performed with using a compact NMR/MRI console [2] and RF solenoid coil. A NMR spectrum of Ethanol (CH3OH2OH, 4cc) was measured with using higher order shim coils. A human finger in vivo was imaged using a conventional 3D spin echo sequence; TR/TE = 200/16 ms, matrix = 256×128×32, Tacq = 8min, voxcel size 100 um× 200 um× 800 um. Result and discussions The H spectrum of Ethanol in a tube is shown in figure 3. As a result of the achievement for a few ppm of the field homogeneity with the shim coils, chemical sifts of three different intensities representing CH3, CH2, and OH ware acquired. The MR microscope images of a human finger are shown in figure 2. The anatomical details in vivo are clearly observed in this image. One of the advantages for NMR/MRI systems with permanent magnets is that we can use RF solenoid coils for signal detections. In theory the SNR for solenoid RF coil is twice as much as the SNR for a quadrature birdcage coil in the same diameter of its coil dimension. According to the above estimation, a combination of the 2.0T and solenoid rivals a super-conducting 4.0T system at SNR. Conclusion The first trial of development for a 2.0T permanent magnet for NMR/MRI was successfully done.The combination of the 2.0T and solenoid rivals 4.0T systems at SNR. The NMR/MRI experimentswere performed with using a compact NMR/MRI console and RF solenoid coil. This resultpromises the stability and wide-use of the maintenance-free 2.0T magnet.References [1]Tomoyuki Haishi et al, Magnetic Resonance Imaging, 19, 875-880, 2001[2]K. Kose et al, MRMics, 6th ISMRM, Sydney, 1998[3]Tomoyuki Haishi, ICMRM proceedings, Snowbird, Utah, USA, 2003[4]M. Aoki, http://www.neomax.co.jp/ Fig.3. H spectrum of Ethanol acquired with the 2.0Tmagnet Fig.4. Column type circuit Fig.5. Halbach circuit (4.4T) Fig.6. Yolkless circuit1kHz/DIVFig.2. MRM image of a human finger in vivo; 3D-SE, 256x128x32, TR/TE=100/16, NEX=1,100umx200umx800um, Tacq=8minFig.1. NMR/MRI system with a 2.0T permanentmagnetic circuit and console.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Magnetic Graphene Oxide Nanocarrier as a drug delivery vehicle for MRI monitored magnetic targeting of rat brain tumors

Introduction: Glioblastoma multiform is the most common malignant brain tumor, with an invasive nature. Despite the development of conventional therapies such as surgery, radiotherapy and chemotherapy, because of high recurrence rates, the prognosis remains very poor. Over the last decade, nanotechnology has represented an innovative method as nanoparticle-based drug delivery ...

متن کامل

Morphologic Evaluation of the Fertilized and Unfertilized Ostrich Egg during the Early Stages of Development (MRI Analysis)

Introduction: The magnetic resonance imaging (MRI) technique permits to monitor the development of the embryo in vivo without causing any developmental defects. Although increasing application of MRI imaging are predicted in veterinary sciences, there is little information available about MRI studies of avian embryos and their eggs. The objective of the present study was to evaluate the o...

متن کامل

A Complete Digital Magnetic Resonance Imaging (MRI) System at Low Magnetic Field (0.1 Tesla)

A new complete digital MRI system is developed to enhance the signal-to-noise ratio of the detected nuclear magnetic resonance(NMR) signals at low magnetic field (0.1 Tesla). The system is based on digital signal processor (DSP) that functions also as a controller and as an interface between the frequency translator and the digital synthesiser. The final system should be “portable” functioning ...

متن کامل

High resolution NMR imaging using a high field yokeless permanent magnet.

We measured the homogeneity and stability of the magnetic field of a high field (about 1.04 tesla) yokeless permanent magnet with 40-mm gap for high resolution nuclear magnetic resonance (NMR) imaging. Homogeneity was evaluated using a 3-dimensional (3D) lattice phantom and 3D spin-echo imaging sequences. In the central sphere (20-mm diameter), peak-to-peak magnetic field inhomogeneity was abou...

متن کامل

Cardiac pacemakers and implantable cardioverter defibrillators: in vitro magnetic resonance imaging evaluation at 1.5-tesla.

RATIONALE AND OBJECTIVES To evaluate the effect of Magnetic Resonance Imaging (MRI) performed at 1.5-Tesla on current generation pacemakers and ICDs to identify safe parameters for MRI examinations. METHODS Pacemakers (Identity ADx XL DR+ 5386 and Identity ADx DR + 5380 generators; 1688T/52-cm atrial and ventricular leads) and ICDs (Atlas + V-243, Epic + V-236, and Epic + HF V-350 generators;...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005