Modelling and performance analysis of an adaptive state-transition approach for power saving in Bluetooth
نویسندگان
چکیده
In this paper, an approach is developed to improve the power efficiency of Bluetooth. The better efficiency is achieved by reducing the unnecessary polling operations in the Basic Rate/Enhanced Data Rate (BR/EDR) controllers. An analysis of the current low power modes in the Bluetooth BR/EDR controller indicates that their activation requires a critical and challenging parameter negotiation phase. These parameters have a wide range of choices and as a result the associated low power modes are typically ignored by the Bluetooth application developers. The new approach is based upon multiple polling intervals. It is shown that three different polling intervals: small, medium and large are sufficient for a broad range of data traffic scenarios. As the kernel idea, each controller runs a common algorithm to choose among the three polling intervals and adaptively switches link state between the active data transfer state and idle. The state-transition rules are derived, and a system model is established based on the Hidden Markov Model (HMM), which is used to analyze and design the new Bluetooth link state-transition algorithm. The simulation and analysis demonstrates significant power saving and relatively low average end-toend packet delay for this state-transition based approach, in comparison to the conventional polling system and the low power sniff mode. Moreover, the state-transition approach enables easier parameter setting that can be further optimized for a specific Bluetooth scenario. 2012 Elsevier B.V. All rights reserved.
منابع مشابه
Reliability Assessment of Power Generation Systems in Presence of Wind Farms Using Fuzzy Logic Method
A wind farm is a collection of wind turbines built in an area to provide electricity. Wind power is a renewable energy resource and an alternative to non-renewable fossil fuels. In this paper impact of wind farms in power system reliability is investigate and a new procedure for reliability assessment of wind farms in HL1 level is proposed. In proposed procedure, application of Fuzzy – Markov f...
متن کاملThermodynamic modeling and comprehensive off-design performance analysis of a real integrated solar combined cycle power plant
In this paper thermodynamic modeling and comprehensive performance analysis of a real integrated solar combined cycle (ISCC) power plant are performed. Performance of the plant cycle is assessed in off-design condition and in two operation modes of power-boosting and fuel-saving. Such an approach has not been considered for an ISCC plant in the previous studies. Under studied ISCC which is loca...
متن کاملModelling and Simulation of Low-Head Hydro Turbine for Small Signal Stability Analysis in Power System
The hydro turbine dynamics have a considerable influence on the dynamic stability of power system. In the study of dynamic stability, the system is modeled by the linear differential equations (small signal analysis). Small signal stability of power systems is needed in all conditions and only is dependent on the conditions of power system performance before commotion occurrence. This paper pr...
متن کاملAdaptive Sliding Mode Control of Multi-DG, Multi-Bus Grid-Connected Microgrid
This paper proposes a new adaptive controller for the robust control of a grid-connected multi-DG microgrid (MG) with the main aim of output active power and reactive power regulation as well as busbar voltage regulation of DGs. In addition, this paper proposes a simple systematic method for the dynamic analysis including the shunt and series faults that are assumed to occur in the MG. The pres...
متن کاملA Markov Model for Performance Evaluation of Coal Handling Unit of a Thermal Power Plant
The present paper discusses the development of a Markov model for performance evaluation of coal handling unit of a thermal power plant using probabilistic approach. Coal handling unit ensures proper supply of coal for sound functioning of thermal Power Plant. In present paper, the coal handling unit consists of two subsystems with two possible states i.e. working and failed. Failure and repair...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Simulation Modelling Practice and Theory
دوره 31 شماره
صفحات -
تاریخ انتشار 2013