Comparison of 60Co and 192Ir sources in HDR brachytherapy

نویسندگان

  • Stefan Strohmaier
  • Grzegorz Zwierzchowski
چکیده

This paper compares the isotopes (60)Co and (192)Ir as radiation sources for high-dose-rate (HDR) afterloading brachytherapy. The smaller size of (192)Ir sources made it the preferred radionuclide for temporary brachytherapy treatments. Recently also (60)Co sources have been made available with identical geometrical dimensions. This paper compares the characteristics of both nuclides in different fields of brachytherapy based on scientific literature. In an additional part of this paper reports from medical physicists of several radiation therapy institutes are discussed. The purpose of this work is to investigate the advantages or disadvantages of both radionuclides for HDR brachytherapy due to their physical differences. The motivation is to provide useful information to support decision-making procedures in the selection of equipment for brachytherapy treatment rooms. The results of this work show that no advantages or disadvantages exist for (60)Co sources compared to (192)Ir sources with regard to clinical aspects. Nevertheless, there are potential logistical advantages of (60)Co sources due to its longer half-life (5.3 years vs. 74 days), making it an interesting alternative especially in developing countries.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Verification of delivered dose to the Lips carcinoma tumors with HDR brachytherapy sources: 192Ir and 60CO in an exclusive plexiglass Phantom.

Introduction: Brachytherapy, especially using manually after loaded Iridium-192 and Cobalt-60, can be applied as a sole treatment, as a treatment complementary to surgery, and as a local boost in combination with EBRT. The use of HDR brachytherapy catheters incorporated in removable dental molds allows repeated, highly reproducible, fractionated outpatient brachytherapy of supe...

متن کامل

Evaluation of dose distribution and dose gradient in brachytherapy cylindrical applicators using a dedicated Phantom for Iridium-192 and Cobalt-60 HDR sources

Introduction: A study was performed to evaluate radiation dose distribution and dose gradient around cylindrical applicators for high-dose-rate (HDR) brachytherapy systems with 192Ir, 60Co brachytherapy source applied for rectal and vaginal cancers treatments.   Materials and Methods: Two additional computed tomography (CT) based plans were generated using a ...

متن کامل

Comparison the treatment time of cobalt and iridium sources in HDR brachytherapy

Introduction: The use of long-half-life Cobalt source instead of iridium source will be very helpful in HDR brachytherapy for treatment of cervical cancer. The aim of this study was compared the treatment time with cobalt and iridium source in brachytherapy for treatment of cervical cancer using Tandem-ovoid applicator. Materials and Methods: In this study, 19...

متن کامل

A comparative assessment of inhomogeneity and finite patient dimension effects in 60Co and 192Ir high-dose-rate brachytherapy

Purpose To perform a comparative study of heterogeneities and finite patient dimension effects in 60Co and 192Ir high-dose-rate (HDR) brachytherapy. Material and methods Clinically equivalent plans were prepared for 19 cases (8 breast, 5 esophagus, 6 gynecologic) using the Ir2.A85-2 and the Co0.A86 HDR sources, with a TG-43 based treatment planning system (TPS). Phase space files were obtaine...

متن کامل

Monte Carlo Calculation of Beam Quality and Phantom Scatter Corrections for Lithium Formate Electron Paramagnetic Resonance Dosimeter for High-energy Brachytherapy Dosimetry

PURPOSE To investigate beam quality correction, KQQ0 (r) and phantom scatter correction, Kphan (r) for lithium formate dosimeter as a function of distance r along the transverse axis of the high-energy brachytherapy sources 60Co, 137Cs, 192Ir and 169Yb using the Monte Carlo-based EGSnrc code system. MATERIALS AND METHODS The brachytherapy sources investigated in this study are BEBIG High Dose...

متن کامل

Calibration of iridium-192 source by ionization chamber for high dose rate brachytherapy

Background: The effectiveness and safety of brachytherapy treatment is mainly concerned with the calibration of sources and their traceability to internationally accepted Standards. Secondary Standard Dosimetry Laboratory (SSDL) does not offer calibration of ionization chambers with gamma-ray spectrum of high dose rate source 192Ir . This work has been carried out to calibrate the high dose rat...

متن کامل