Carbon-carbon composite bearing materials in hip arthroplasty: analysis of wear and biological response to wear debris.

نویسندگان

  • G I Howling
  • E Ingham
  • H Sakoda
  • T D Stewart
  • J Fisher
  • A Antonarulrajah
  • S Appleyard
  • B Rand
چکیده

Ultra-high molecular weight polyethylene wear particles have been implicated as the major cause of osteolysis, implant loosening and late aseptic failure in total hip arthroplasties in vivo. This study initially screened 22 carbon-carbon composite materials as alternatives for UHMWPE in joint bearings. New bearing materials should satisfy certain criteria--they should have good wear properties that at least match UHMWPE, and produce wear particles with low levels of cytotoxic and osteolytic activity. Initial screening was based on wear resistance determined in short-term tribological pin-on-plate tests. Three materials (HMU-PP(s), HMU-RC-P(s), and SMS-RC-P(s)) which had superior wear resistance were selected for long-term testing. All materials had very low wear factors and SMS-RC-P(s), which had a wear factor of 0.08 +/- 0.56 x 10(-7) mm3/Nm, was selected for the subsequent biological testing and particle size analysis. SMS-RC-P(s) showed good biocompatibility in bulk material form and also the wear particles had low cytotoxicity for L929 fibroblasts in culture compared to metal wear particles. Wear debris size analysis by transmission electron microscopy showed that the particles were very small, with the vast majority being under 100 nm in size, similar to metal wear particles. The potential osteolytic effect of SMS-RC-P(s) wear particles was investigated by culturing particles with human peripheral blood mononuclear cells and measuring TNFalpha production. SMS-RC-P(s) did not significantly stimulate TNFalpha production at a particle volume to cell number ratio of 80:1, indicating that the debris had a low osteolytic potential. The results of this study suggest that carbon-carbon composites, particularly those composed of PAN-based fibers may be important biomaterials in the development of next generation bearing surfaces for use in total joint replacements that have very low wear rates and reduced osteolytic and cytotoxic potential.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Wear and Wear Debris Generated from Ceramic-on-Carbon Fibre Reinforced PEEK Hip Replacements

INTRODUCTION Concerns regarding UHMWPE wear particle induced osteolysis [1] have led to investigations of alternative bearing materials. Carbon-fibre reinforced poly-ether-ether-ketone (CFR-PEEK) has been shown in animal studies to have a similar biological activity to UHMWPE [2], whilst hip and knee configurations incorporating this polymer display reduced wear rates when compared with convent...

متن کامل

Evaluation of Mechanical and Tribological Properties of Glass/Carbon Fiber Reinforced Polymer Hybrid Composite

Polymer matrix composites used in different industrial applications due to their enhanced mechanical properties and lightweight. However, these materials are subjected to friction and wear situations in some industrial and automobile applications. Therefore, there is a need to investigate the wear properties of polymer matrix composite materials. This article emphasizes the dry abrasive wear be...

متن کامل

Technical and histologic analysis of a retrieved carbon fiber-reinforced poly-ether-ether-ketone composite alumina-bearing liner 28 months after implantation.

A new innovative low-wear bearing for use in total hip arthroplasty, a wear couple consisting of carbon fiber-reinforced poly-ether-ether-ketone (CF-PEEK), has been shown to be highly biocompatible and to have excellent tribological performance in the laboratory. We report the results of our technical and histologic analysis of a CF-PEEK composite acetabular cup component articulating against a...

متن کامل

Effect of carbon ion implantation on the tribology of metal-on-metal bearings for artificial joints

Metal-on-metal (MoM) bearings have become popular due to a major advantage over metal-on-polymer bearings for total hip arthroplasty in that the larger femoral head and hydrodynamic lubrication of the former reduce the rate of wear. However, concerns remain regarding adverse reactions to metal debris including metallosis caused by metal wear generated at the taper-head interface and another mod...

متن کامل

Wear of ceramic-on-carbon fibre reinforced PEEK hip replacements

Total hip replacement has been a successful surgical intervention for many years. However, concerns regarding UHMWPE wear particle induced osteolysis [1], have led to alternative bearing materials to be sought. Carbon-fibre reinforced poly-ether-ether-ketone (CFR-PEEK) is a fibre-reinforced polymer which has shown reduced wear in hip and knee configurations compared with conventional polyethyle...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of materials science. Materials in medicine

دوره 15 1  شماره 

صفحات  -

تاریخ انتشار 2004