Clinical application of multiphoton tomography in combination with confocal laser scanning microscopy for in vivo evaluation of skin diseases.
نویسندگان
چکیده
Multiphoton tomography (MPT) is an in vivo imaging technique with very high spatial resolution and efforts are made to combine MPT with other non-invasive imaging methods. The goals of the present study were the description of the features of different dermatological entities as seen in MPT and confocal laser scanning microscopy (CLSM) comparison of these two novel techniques and the 'classical' diagnostic measures visual inspection, dermoscopy and histology with respect to the strengths and weaknesses of the different methods and the potential benefit from their combined implementation. After study approval by the local Ethics Committee, 47 patients (31 male, 16 female, age range: 24-88 years) were recruited from the Department of Dermatology of the University Hospital Jena. In this work, we present an illustrative selection of eleven cases from a clinical study combining in vivo MPT with in vivo CLSM. The patients presented with a broad range of dermatological disorders including seborrheic keratoses, angioma, actinic keratoses, melanocytic nevi, malignant melanoma, psoriasis, pemphigus vulgaris and scarring. Both methods, CLSM and MPT, were found to be suitable for in vivo imaging of superficial skin layers and may therefore be useful in dermatological practice for the diagnosis of skin diseases. However, both methods differ in their technical and physical principles. Thus, despite of many similarities concerning the morphological presentation of cells and tissues, important differences are recognized. Synergies of the combination of CLSM and MPT may be obtained by combined implementation in order to benefit from the fast overview given by CLSM and the detailed imaging of skin structures by MPT.
منابع مشابه
Variations of the Normal Human Limbal Stem Cells Detected by In Vivo Confocal Microscopy
Background To report normal variations of the limbal structures using in vivo laser scanning confocal microscopy. Methods: This was a retrospective study of fourteen eyes from 11 healthy individuals. Confocal imaging of cornea and limbus was performed using Heidelberg Retina Tomograph III Rostock Corneal Module. Results: The typical structure of the palisades of Vogt (POV) was detected ...
متن کاملImaging techniques in dermatology
Since the discovery of X-rays, the use of imaging technology has continued to play an important role in medicine. Technological advancements have led to the development of various imaging modalities, most of which have been used to image organs deep within the human body. More recently, attention has focused on the application of imaging technology for evaluation of the skin. A variety of techn...
متن کاملInnovations and Developments in Dermatologic Non-invasive Optical Imaging and Potential Clinical Applications.
Most dermatologists are aware of the benefits of dermoscopy, and a few are familiar with laser-scanning confocal microscopy. Beyond confocal, there are fully 11 different categories of optical techniques that have been applied to clinical dermatology. This article first provides a comprehensive tabular overview of all these optical diagnostic technologies and then details 4 of the lesser known ...
متن کاملSingle-wavelength reflected confocal and multiphoton microscopy for tissue imaging.
Both reflected confocal and multiphoton microscopy can have clinical diagnostic applications. The successful combination of both modalities in tissue imaging enables unique image contrast to be achieved, especially if a single laser excitation wavelength is used. We apply this approach for skin and corneal imaging using the 780-nm output of a femtosecond, titanium-sapphire laser. We find that t...
متن کاملConfocal laser scanning microscopy to estimate nanoparticles’ human skin penetration in vitro
Objective With rapid development of nanotechnology, there is increasing interest in nanoparticle (NP) application and its safety and efficacy on human skin. In this study, we utilized confocal laser scanning microscopy to estimate NP skin penetration. Methods Three different-sized polystyrene NPs marked with red fluorescence were applied to human skin, and Calcium Green 5N was used as a count...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Experimental dermatology
دوره 20 7 شماره
صفحات -
تاریخ انتشار 2011