SINDBAD: a Simulation Software Tool for Multi-energy X-Ray Imaging
نویسندگان
چکیده
The computer simulation of realistic radiographs has been proved to be an efficient tool for the design of X-ray systems, the specification of their components, the development of dedicated image processing methods and the final validation. Sindbad software has been developed at LDET laboratory for that purpose. The goal of this paper is to describe new developments of Sindbad allowing taking into account recently emerged semiconductor based X-ray detectors that offer new capabilities in counting mode with energy discrimination. A model of such detectors is proposed, considering both physical and electronics phenomena. The integration into Sindbad offers spectral imaging simulation functionalities in both radiography and tomographic mode. Examples highlight the energetic dependency of contrast. Validation has been performed, using for comparison semiconductor detectors developed in our laboratory. An example of quantification of beam-hardening artefact illustrates the influence of detector characteristics on image quality.
منابع مشابه
Dynamic CT simulation for minimal invasive surgery
Dynamic X-ray Computed Tomography (CT) is an attractive imaging technology for the guidance in minimal invasive surgery. In this field, projection data simulation is an important tool to optimise scanner geometry and to validate reconstruction algorithms. A realistic simulation software, called “Sindbad” has been developed to compute 2D projections. It is based on an analytical model and allows...
متن کاملRecent Improvements for Scatter Simulation in Sindbad, a Coupled Photon Monte Carlo and Cad Software
In an X-ray radiography, scattering of photons from the inspected object, as well as backscattering or scattering from the environment, may have significant deleterious effects on image quality, reducing the relative contrast of the flaw indication. Therefore, development of computational models simulating scattering in radiographic studies is of primary interest, to correctly evaluate flaw det...
متن کاملEvaluation of X-ray absorbed dose in thyroid during CXR imaging of the chest by Monte Carlo simulation (DOSXYZnrc)
Abstract: Introduction: Chest radiography is one of the most common X-ray imaging procedures performed worldwide. During this process, in addition to the chest, other tissues, including the thyroid, are also exposed to radiation. Due to the fact that one of the most important risk factors for thyroid cancer is ionizing radiation, measuring the absorption of X- rays in the thyroid is of spec...
متن کاملImpact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography
Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...
متن کاملبررسی امکان تشخیص اتوماتیک میکروکلسیم های بافت پستان با استفاده از تکنیک دو انرژی تصویربرداری اشعه ایکس جهت تشخیص زودرس سرطان پستان
Background and purpose: Dual-energy mammography technique is used for improving the accuracy of breast cancer diagnosis especially in dense breast cases and also detection of micro-calcifications which are early signs of breast cancer. The purpose of this study was to investigate the automatic separation feasibility of micro-calcification images in breast tissue images and evaluating its accura...
متن کامل