A clinical evaluation of a sensor to detect blockage due to crystalline biofilm formation on indwelling urinary catheters.

نویسندگان

  • Adele Long
  • Julia Edwards
  • Richard Thompson
  • Debbie A Lewis
  • Anthony G Timoney
چکیده

OBJECTIVE To test the performance and acceptability of an early warning sensor to predict encrustation and blockage of long-term indwelling urinary catheters. PATIENTS AND METHODS In all, 17 long-term indwelling catheter users, 15 'blockers' and two 'non-blockers' (controls) were recruited; 11 participants were followed prospectively until catheter change, three withdrew early and three did not start. Two sensors were placed in series between the catheter and the urine bag at catheter change. The sensor nearest the bag was changed at the same time as the bag change (weekly); the sensor nearest the catheter remained in situ for the duration of the catheter's life. Bacteriology and pH determinations were performed on urine samples at each bag, sensor and catheter change. The colour of the sensors was recorded daily. On removal, each sensor and the catheter were examined for visible evidence of encrustation and blockage. Participants were asked to keep a daily diary to record colour change and any other relevant observations and to complete a psychosocial impact of assistive devices tool at the end of the study. Participants and carers/healthcare professionals (when involved in urine bag or catheter change) were asked to complete a questionnaire about the sensor. RESULTS Urease-producing bacteria were isolated from seven of the 14 patients (including early withdrawals; P. mirabilis in four, Morganella or Providencia in three). In six of the seven patients the sensors turned blue-black; two of these were early withdrawals, two went to planned catheter change (one of these was recruited as a 'non-blocker') and three had catheter blockage. The number of days of catheterisation before blockage was 22, 23 and 25 days, and the sensor changed colour within 24-48 h after insertion. The urine mean (range) pH of the sensors that turned blue-black was 7.6 (5.5-9.0) and of the sensors that remained yellow 6.1 (5.1-7.5). The sensor was generally well-received and was positive in the psychosocial assessment. CONCLUSIONS The sensor is a useful indicator of urine pH and of the conditions that lead to catheter blockage. It may be particularly useful for new indwelling catheter users. To be a universally acceptable predictor of catheter blockage, the time from sensor colour change to blockage needs to be reduced.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A sensor to detect the early stages in the development of crystalline Proteus mirabilis biofilm on indwelling bladder catheters.

A simple sensor has been developed to detect the early stages of urinary catheter encrustation and avoid the clinical crises induced by catheter blockage. In laboratory models of colonization by Proteus mirabilis, the sensor signaled encrustation at an average time of 43 h before catheters were blocked with crystalline biofilm.

متن کامل

Control of encrustation and blockage of Foley catheters.

Urinary catheters often become encrusted and blocked by crystalline Proteus mirabilis biofilms. Results of experiments in a laboratory model of a Foley catheterised bladder infected with P mirabilis showed that when retention balloons were inflated with a solution of triclosan (10 g/L), the catheters drained freely for at least 7 days. Triclosan became impregnated throughout the silicone cathet...

متن کامل

Prevention of encrustation and blockage of urinary catheters by Proteus mirabilis via pH-triggered release of bacteriophage

The crystalline biofilms of Proteus mirabilis can seriously complicate the care of patients undergoing long-term indwelling urinary catheterisation. Expression of bacterial urease causes a significant increase in urinary pH, leading to the supersaturation and precipitation of struvite and apatite crystals. These crystals become lodged within the biofilm, resulting in the blockage of urine flow ...

متن کامل

Novel Insights into the Proteus mirabilis Crystalline Biofilm Using Real-Time Imaging

The long-term use of indwelling catheters results in a high risk from urinary tract infections (UTI) and blockage. Blockages often occur from crystalline deposits, formed as the pH rises due to the action of urease-producing bacteria; the most commonly found species being Proteus mirabilis. These crystalline biofilms have been found to develop on all catheter materials with P. mirabilis attachi...

متن کامل

Bacteriophage Can Prevent Encrustation and Blockage of Urinary Catheters by Proteus mirabilis.

Proteus mirabilis forms dense crystalline biofilms on catheter surfaces that occlude urine flow, leading to serious clinical complications in long-term catheterized patients, but there are presently no truly effective approaches to control catheter blockage by this organism. This study evaluated the potential for bacteriophage therapy to control P. mirabilis infection and prevent catheter block...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • BJU international

دوره 114 2  شماره 

صفحات  -

تاریخ انتشار 2014