Dobutamine stress tetrofosmin SPECT; evaluation of short rest-stress protocol and head to head comparison with MIBI in detection of coronary artery disease.
نویسندگان
چکیده
OBJECTIVE The purpose of the present study was to evaluate the feasibility and diagnostic accuracy of same day short rest-dobutamine stress Tetrofosmin (TF) SPECT imaging protocol and to compare TF SPECT results with MIBI SPECT in the same subjects who were unable to perform treadmill exercise or were unsuitable for pharmacological vasodilator stress. METHODS The study group consisted of 19 patients (2 female and 17 male, with a mean age of 53.8 +/- 7.9 yrs) in whom coronary artery disease (CAD) had been proven or excluded at coronary angiography (CA). MIBI SPECT imaging was performed first. TF SPECT images were obtained one week after MIBI imaging. Immediately after the rest SPECT imaging in both of the MIBI and TF studies, patients underwent dobutamine stress tests. Rest-stress radiotracer doses and dobutamine doses were the same for both TF and MIBI studies. While 60 min waiting periods were applied for MIBI study, only 30 min waiting periods were applied for TF study after the rest and stress injections. Images were evaluated by visual and quantitative analysis. RESULTS Dobutamine stress parameters were similar for both studies. Although in TF study, the time between radiopharmaceutical injection and imaging was shorter than in MIBI study, there was no significant difference between heart-to-liver (H/Li) and heart-to-lung (H/Lu) ratios. According to CA results, diagnostic accuracy was similar for TF and MIBI. While sensitivity, specificity and accuracy for TF study were calculated as 82%, 84% and 82%, respectively, the corresponding values for MIBI were 82%, 88% and 84%, respectively. This clinical study has shown comparable diagnostic performance for the detection of CAD between MIBI and TF. Good correlation was found between segmental analysis for both studies. CONCLUSION MIBI and TF showed similar perfusion defects and good segmental correlation during dobutamine stress with the same quality images. Both radiopharmaceuticals may be acceptable with this imaging protocol. Besides this, TF study showed better reversibility degree (55%) in a shorter time when compared to MIBI study (25%) in perfusion defects (especially in segments with severely decreased perfusion or no uptake).
منابع مشابه
Myocardial perfusion scan accuracy in detection of coronary artery disease - Comparison with exercise stress test [Persian]
Introduction: In patients with coronary artery disease (CAD) noninvasive evaluation for detection of ischemia is important to avoid invasive interventions like angiography. Exercise stress test is conventionally the first study used in evaluation of CAD. Considering the noninvasive nature of the myocardial perfusion scan, we decided to compare its accuracy with stress test. Methods: Patie...
متن کاملComparison of 201Tl, 99mTc-tetrofosmin, and dobutamine magnetic resonance imaging for identifying hibernating myocardium.
BACKGROUND Both radionuclide perfusion tracers and contractile response to dobutamine have been used to identify hibernating myocardium. The aim was to compare 201Tl (thallium) single photon emission CT (SPECT), 99mTc-tetrofosmin (tetrofosmin) SPECT, and dobutamine cine MRI for identifying regions of reversible myocardial dysfunction. METHODS AND RESULTS Thirty patients with 3-vessel coronary...
متن کاملComparison of Tl, Tc-Tetrofosmin, and Dobutamine Magnetic Resonance Imaging for Identifying Hibernating Myocardium
Background—Both radionuclide perfusion tracers and contractile response to dobutamine have been used to identify hibernating myocardium. The aim was to compare Tl (thallium) single photon emission CT (SPECT), Tctetrofosmin (tetrofosmin) SPECT, and dobutamine cine MRI for identifying regions of reversible myocardial dysfunction. Methods and Results—Thirty patients with 3-vessel coronary artery d...
متن کاملGated 99mTc-MIBI myocardial perfusion SPECT in patients with right bundle branch block but without evidence of coronary artery disease
Introduction: We aimed to investigate the effect of right bundle branch block (RBBB) on perfusion and functional parameters in dipyridamole stress/rest Tc99m-MIBI gated myocardial perfusion SPECT (GSPECT) which may be helpful in interpretation of myocardial perfusion imaging. Methods: We studied 73 patients with low pre-test likelihood of coronary artery disease in two groups: 38 patients wit...
متن کاملNoninvasive diagnosis of coronary artery stenosis in women with limited exercise capacity: comparison of dobutamine stress echocardiography and 99mTc sestamibi single-photon emission CT.
OBJECTIVES To compare the accuracy of dobutamine stress echocardiography (DSE) and simultaneous 99mTc sestamibi (MIBI) single-photon emission CT (SPECT) imaging for the diagnosis of coronary artery stenosis in women. PATIENTS Seventy women with limited exercise capacity referred for evaluation of myocardial ischemia. METHODS DSE (up to 40 microg/kg/min) was performed in conjunction with str...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Annals of nuclear medicine
دوره 19 2 شماره
صفحات -
تاریخ انتشار 2005