The delta valve: how does its clinical performance compare with two other pressure differential valves without antisiphon control?
نویسندگان
چکیده
OBJECTIVE The Delta valve is a pressure differential valve with a siphon control device. The valve mechanism is normally closed, but is designed to open in response to positive ventricular pressure, thereby avoiding overdrainage of cerebrospinal fluid (CSF). As a result, the incidence of subdural fluid collections as well as postural symptoms is purportedly reduced. In addition, the valve might reduce the number of obstructions as there would be no negative pressure sucking tissue and debris into the shunt system. In order to assess whether use of the Delta valve reduced the number of shunt-related problems as compared with two other pressure differential valves without an antisiphon component, we performed a retrospective review of all children undergoing CSF diversion procedures at our institution. METHODS We reviewed the charts of 1, 193 patients. Cases included 2,325 ventriculoperitoneal (V-P) shunt insertions or revisions from January 1, 1985, to December 31, 1994, performed at our institution. The Delta valve and two pressure differential valves without antisiphon function were exclusively inserted during the following time periods: Holter-Hausner (H-H): January 1, 1985, to August, 1987; Heyer-Schulte (H-S): August, 1987, to June, 1991, and Delta: June, 1991, to December 31, 1994. RESULTS Of the cases reviewed, 475 patients underwent insertion of a V-P shunt at the Childrens Hospital of Los Angeles and had a total of 686 shunt operations. Median follow-up was 3 years and ranged up to 10 years. Kaplan-Meier analysis documented that 67% of H-H, 71% of H-S and 70% of the Delta valves were functioning at 1-year follow-up. At 2-year follow-up, 66% of H-H, 64% of H-S and 65% of the Delta valves were functioning. The difference was not statistically significant. The occurrence rate for symptomatic subdural fluid collections was 0.7% (1/130) for H-H, 2.2% (3/139) for H-S and 1.0% (2/206) for the Delta valve (p = 0.52). The combined breakage/obstruction rate for the series was 7.7% (10/130) for H-H, 2.9% (4/139) for H-S and 4.9% (10/206) for the Delta valve (p = 0.19). No Delta valves malfunctioned secondary to fibrous capsule affecting the antisiphon device. CONCLUSIONS In conclusion, it appears that performance of the Delta valve was not significantly different from the H-H and H-S valves, two valves without an antisiphon device. There was no significant difference in the occurrence of symptomatic subdural fluid collections based upon valve type, or in the combined valve breakage/obstruction rates based upon valve type.
منابع مشابه
Shunt Devices for the Treatment of Adult Hydrocephalus: Recent Progress and Characteristics
Various types of shunt valves have been developed during the past 50 years, most of which can be classified into the following categories: (1) fixed differential pressure valves; (2) fixed differential pressure (DP) valves with an antisiphon mechanism; (3) programmable DP valves; (4) programmable DP valves with an antisiphon mechanism; and (5) programmable antisiphon valves. When considering th...
متن کاملInfluence of Pipeline Operating Pressure on Value Setting of Automatic Control Valves at Different Pressure Drop Rates
When a natural gas pipeline ruptures, the adjacent upstream and downstream automatic control valves (ACV) should close quickly to prevent leakage or explosion. The differential pressure set point (DPS) at each valve location is the main criteria for value setting in ACV actions. If the DPS is not properly adjusted, the ACV may mistakenly close or it may not take any actions at a proper ti...
متن کاملCerebrospinal fluid shunt dynamics in patients with idiopathic adult hydrocephalus syndrome.
The objective was to assess CSF dynamics of different shunt constructions in patients with adult hydrocephalus syndrome and correlate these findings to clinical outcome, neuroradiology, and the specifications of the shunts provided by the manufacturer. Thirty four patients with idiopathic adult hydrocephalus (normal pressure hydrocephalus) syndrome were included in a prospective, consecutive ca...
متن کاملExperimental values for adjusting an automatic control valve in gas pipeline transportation
When a natural gas pipeline ruptures, the adjacent automatic line control valves (ALCVs) should close quickly to prevent leakage or explosion. The differential pressure set point (DPS) at each valve location is the main criteria for value setting in ALCV action. If the DPS is not properly adjusted, the ALCV may mistakenly close or it may not take any action at proper time. This study focused on...
متن کاملComparison of Clinical Outcomes Seprate and semi continus sewing methods during and after Heart valves Surgery
Background and Aims: Various therapies and surgeries are applied in heart valve surgery, including interrupted and semi-continuous suture techniques. Therefore, this study aimed to compare the clinical implications of two methods of interrupted and semi-continuous suture techniques during and after mitral or aortic valve replacement surgery among patients referred to Department of Surgery, Scho...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Pediatric neurosurgery
دوره 33 2 شماره
صفحات -
تاریخ انتشار 2000