Evaluation of Intravenous Infusion Systems for Adenosine
نویسنده
چکیده
Adenosine is used routinely in cardiac perfusion imaging in lieu of exercise stress to enhance coronary blood flow. Since it is a potent drug, intravenous (IV) infusion of adenosine must be carefully controlled to provide optimal pharmacologic effect and minimal adverse effects. There has been particular concern about a sudden increase in adenosine delivery at the time of radiotracer administration which has prompted recommendations for using separate IV infusion sites or double lumen IV catheter sets. To evaluate infusion control, five IV infusion systems were evaluated for their ability to accurately deliver adenosine with co-administration of a radiopharmaceutical, such as thallium-201 eo•Tt) into the infusion line. A decrease in adenosine infusion occurred with the Buretrol gravity drip system when 201 T/ was injected into the infusion line. A temporary, intermittent decrease of adenosine infusion also occurred with the IMED infusion system because of its pumping mechanism. No significant change in adenosine infusion occurred with either the Harvard or Medfusion syringe pumps or with the IVAC infusion pump. No significant increase or bolus effect of adenosine administration occurred with any of the infusion systems.
منابع مشابه
Intracoronary electrocardiogram ST segment shift evaluation during intravenous adenosine infusion: a comparison with fractional flow reserve.
BACKGROUND By measuring the pressure decline caused by coronary narrowing, fractional flow reserve (FFR) is an index of the physiological significance of a vessel stenosis. Intracoronary electrocardiogram (IC-ECG) recording from an angioplasty guidewire is more sensitive than standard ECG in detecting regional myocardial ischemia. The aim of the study was to assess if unipolar IC-ECG ST segment...
متن کاملEvaluation of Intravenous Lidocaine Overdose in Chickens (Gallus domesticus)
Objective- To evaluate the total toxic dose of lidocaine and serum lidocaine concentrations resulting in clinical signs of toxicity in chickens. Design- Experimental study Animals- Eight healthy, female, 55-week-old chickens (Lohman breed) weighing 1.45 ± 0.17 kg (mean ± SD) Procedure- A loading dose of 2% lidocaine (4 mg/kg) was administered IV, followed by a constant-rate infusion at a dose o...
متن کاملThe effects of short term intravenous infusion of a soybean based lipid emulsion on some blood constituents in sheep: A preliminary study
To evaluate the effect of intravenous infusion of a soybean based lipid emulsion (Lipovenoes 10%) on some blood constituents in sheep, a replicated 2 × 2 Latin square design experiment was conducted in four clinically healthy ewes. Lipid emulsion (LE group) or normal saline (NS group) was infused intravenously at a rate of 0.025 mL kg-1 per min for 6 hr and the concentrations of bloo...
متن کاملHeparin Resistance During and Post-Intravenous Nitroglycerin Infusion
Nitroglycerin has been reported to reduce activated partial thromboplastin time (aPTT) values in patients treated with concurrent heparin and nitroglycerin. However, studies have yielded conflicting results. To determine whether intravenous nitroglycerin alters the anticoagulant effect of heparin, we prospectively evaluated twenty patients admitted for coronary angioplasty by measurin...
متن کاملEffect of adenosine infusion on oxygen induced carbon dioxide retention in severe chronic obstructive pulmonary disease.
BACKGROUND In normal subjects intravenous adenosine infusion has been shown to stimulate ventilation with a consequent fall in arterial partial pressure of carbon dioxide (Paco2), probably by an action on the carotid bodies. The objective of this study was to determine whether the increase in Paco2 seen when patients with ventilatory failure secondary to chronic obstructive pulmonary disease (C...
متن کامل