Forearm skin tissue dielectric constant measured at 300 MHz: effect of changes in skin vascular volume and blood flow.

نویسندگان

  • Harvey N Mayrovitz
  • Xiaoran Guo
  • Mark Salmon
  • Matt Uhde
چکیده

Skin tissue dielectric constant (TDC) values measured via the open-ended coaxial probe method are useful non-invasive indices of local skin tissue water. However, the effect of skin blood flow (SBF) or skin blood volume (SBV) on TDC values is unknown. To determine the magnitude of such effects, we decreased forearm SBV via vertical arm raising for 5 min (test 1) and increased SBV by bicep cuff compression to 50 mmHg for 5 min (test 2) in 20 healthy supine subjects (10 men). TDC values were measured to a depth of 1·5 mm on anterior forearm, and SBF was measured with laser-Doppler system simultaneously on forearm and finger. Results indicate that decreasing vascular volume (test 1) was associated with a small but statistically significant reduction in TDC (3·0 ± 4·3%, P = 0·003) and increasing vascular volume (test 2) was associated with a slight but statistically significant increase in TDC (3·5 ± 3·0%, P<0·001). SBF changes depended on test and measurement site. For forearm, test 1 significantly increased SBF (102·6 ± 156·2%, P<0·001) and test 2 significantly decreased it (39·5 ± 13·1%, P<0·001). In finger, SBF was significantly reduced by both tests: in test 1 by 55·3 ± 32·1%, P<0·001 and in test 2 by 53·3 ± 27·6%, P<0·001. We conclude that the small percentage changes in TDC values (3·0-3·5%) over the wide range of induced SBV and SBF changes suggest a minor effect on clinically determined TDC values because of SBV or SBF changes or differences when comparing TDC longitudinally over time or among individuals of different groups in a research setting.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Gender differences in facial skin dielectric constant measured at 300 MHz.

BACKGROUND/PURPOSE Skin tissue dielectric constant (TDC) measurements at 300 MHz provide non-invasive data on free and bound tissue water. TDC-data is available for some body sites, but most is for female forearm. Contrastingly, there are no data on face-skin or comparative data between genders. Our goals were to obtain facial-TDC reference values and determine if TDC-values differ between gend...

متن کامل

Race-related differences in tissue dielectric constant measured noninvasively at 300 MHz in male and female skin at multiple sites and depths.

BACKGROUND/PURPOSE We hypothesized that reported race-related differences in skin properties cause skin and skin-to-fat water differences among races that are measureable by skin tissue dielectric constant (TDC) values that depend strongly on water content. Our first aim was to test this hypothesis. Also, since inter-side TDC ratios are used to assess edema and lymphedema, the second aim was to...

متن کامل

Age-related differences in tissue dielectric constant values of female forearm skin measured noninvasively at 300 MHz.

BACKGROUND/PURPOSE We hypothesized that reported age-related shifts in skin water from less-to-more mobile states would result in increased skin tissue dielectric constant (TDC) values as TDC values depend strongly on water content and state. One aim was to test this hypothesis. Further, as skin-to-fat TDC values are used as a tool for edema and lymphedema assessment, a second aim was to establ...

متن کامل

Male-female differences in forearm skin tissue dielectric constant.

Tissue dielectric constant (TDC) measurements at 300 MHz via the coaxial line reflection method are useful to evaluate local skin tissue water and its change, but virtually all available data relate to measurements on women. Because TDC values in part depend on skin thickness, we hypothesized that differences in male-female skin may be associated with male-female differences in TDC. To test thi...

متن کامل

Biophysical measures of skin tissue water: variations within and among anatomical sites and correlations between measures.

BACKGROUND Biophysical measures to assess that skin water includes stratum corneum hydration via capacitance (SC), dermal water via tissue dielectric constant (TDC), and transepidermal water loss (TEWL). Since skin differs among anatomical sites and tissue depth we sought to determine the site and depth variability of these measures and their relationships. METHODS Measurements were done at 1...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical physiology and functional imaging

دوره 33 1  شماره 

صفحات  -

تاریخ انتشار 2013