Influence of luminal diameters on flow surveillance of hemodialysis grafts: insights from a mathematical model.

نویسندگان

  • John J White
  • Sunanda J Ram
  • Steven A Jones
  • Steve J Schwab
  • William D Paulson
چکیده

Randomized controlled trials have not shown that surveillance of graft blood flow (Q) prolongs graft life. Because luminal diameters affect flow resistance, this study examined whether the influence of diameters on Q can explain the limitations of surveillance. Inflow artery and outflow vein diameters were determined from duplex ultrasound studies of 94 patients. These diameters were applied to a mathematical model for determination of how they affect the relation between Q and stenosis. Also determined was the correlation between Q (by ultrasound dilution) and diameters, stenosis, and mean arterial pressure in 88 patients. Artery and vein diameters varied widely between patients, but arteries generally were narrower than veins. The model predicts that the relation between Q and stenosis is sigmoid: as stenosis progresses, Q initially remains unchanged but then rapidly decreases. A narrower artery increases flow resistance, causing a longer delay followed by a more rapid reduction in Q. In a multiple regression analysis of data from patients, Q correlated with artery and vein diameters, sum of largest stenoses from each circuit segment, and mean arterial pressure (R = 0.689, P < 0.001). This study helps to explain why Q surveillance predicts thrombosis in some patients but not others. Luminal diameters control the relation between Q and stenosis, and these diameters vary widely. During progressive stenosis, the delay and then rapid reduction in Q may impair recognition of low Q before thrombosis occurs. Surveillance outcomes might be improved by taking frequent measurements so that there is no delay in discovering that Q has decreased.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mathematical model demonstrates influence of luminal diameters on venous pressure surveillance.

BACKGROUND The reliability of dialysis venous pressure (VP) in detecting stenosis is controversial. A mathematical model may help to resolve the controversy by providing insight into the factors that influence static VP. DESIGN, SETTING, PARTICIPANTS, AND MEASUREMENTS This study used inflow artery and outflow vein luminal diameters from duplex ultrasound studies of 94 patients. These diameter...

متن کامل

Translational Insights on Lung Transplantation: Learning from Immunology

The introduction of ex vivo lung perfusion (EVLP) in the practice of lung transplantation has allowed the reconditioning of the marginal grafts and their conversion into transplantable grafts. In addition, EVLP can provide a platform for the application of various preventive measures to decrease the incidence of post-transplant complications. While the Toronto team targets the attenuation of th...

متن کامل

Mathematical Modeling of Fixed Bed Adsorption: Influence of Main Parameters on Breakthrough Curve

Dynamic modeling and simulation of fixed bed adsorption process was carried out by explaining the behavior of breakthrough curve parameter. Adsorption of sulfur compound, present in road fuel, has posed a great challenge. A model of fixed bed adsorption of benzothiophene from fuel was formulated with non-ideal plug flow behavior and considered velocity variation along a column. The model was so...

متن کامل

A Mathematical Model for Blood Flow Through Narrow Vessels with Mild-Stenosis (RESEARCH NOTE)

In this paper we examine the effect of mild stenosis on blood flow, in an irregular axisymmetric artery with oscillating pressure gradient. The Herschel-Bulkley fluid model has been utilized for this study. The combined influence of an asymmetric shape and surface irregularities of constriction has been explored in this computational study. An extensive quantitative analysis has been performed ...

متن کامل

Cardiovascular Surgery Vascular Reactivity and Flow Characteristics of Radial Artery and Long Saphenous Vein Coronary Bypass Grafts A 5-Year Follow-Up

Background— Radial artery (RA) aortocoronary bypass grafts anastomosed to a branch of the circumflex coronary artery have significantly better patency rates than saphenous vein (SV) grafts at 5 years, but the physiological characteristics and mechanisms involved are not clearly defined. We compared RA and SV graft vasomotor and flow responses to endothelium-dependent and -independent stimuli 5 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical journal of the American Society of Nephrology : CJASN

دوره 1 5  شماره 

صفحات  -

تاریخ انتشار 2006