Selection of a DC Solar PV Arc Fault Detector

نویسنده

  • John Kluza
چکیده

1. Executive Summary Arc fault current interruption (AFCI) is required on DC conductors of solar PV installations by NEC 2011 (rooftop systems only) and NEC 2014 (rooftop and ground mount systems). To meet these requirements, combiner boxes for central inverters will need to include arc fault detectors (AFDs) as well as other AFCI equipment. UL recognized AFDs greatly ease the process of listing a combiner box, and there are now a handful of UL recognized devices on the market. Beyond UL recognition, which focuses on arc detection but not real world performance, a desirable AFD needs to perform with a minimum of nuisance tripping while offering competitive cost in terms of both capital expenses (CAPEX or initial costs) and operating expenses (OPEX or operating and maintenance costs).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantifying Photovoltaic Fire Danger Reduction with Arc-fault Circuit Interrupters

Unmitigated arc-faults present fire dangers, shock hazards, and cause system downtime in photovoltaic (PV) systems. The 2011 National Electrical Code® added section 690.11 to require a listed arc-fault protection device on new PV systems. Underwriters Laboratories created the outline of investigation for PV DC arc-fault circuit protection, UL 1699B, for certifying arc-fault circuit interrupters...

متن کامل

Asymmetrical DC-DC Converter with Fault Tolerant Operation Capability for Distributed Generation

As the costs of manufacturing photovoltaic (PV) panels continue to decrease, the use of PV-based solar energy systems is seen in rise across the globe. This paper proposes an asymmetrical DC-DC converter for standalone solar energy systems. The converter is developed to control modularized PV panels with a combination of soft-switching, flyback-forward, high-step-up voltage ratio, and fault tol...

متن کامل

Development of Fault Detector for Series Arc Fault in Low Voltage DC Distribution System using Wavelet Singular Value Decomposition and State Diagram

It is well known that series arc faults in Low Voltage DC (LVDC) distribution system occur at unintended points of discontinuity within an electrical circuit. These faults can make circuit breakers not respond timely due to low fault current. It, therefore, is needed to detect the series fault for protecting circuits from electrical fires. This paper proposes a novel scheme to detect the series...

متن کامل

PV arc-fault feature extraction and detection based on bayesian support vector machines

In a PV system, DC arc is regarded as a serious fault, which might cause circuit damage and trigger fires. The arc fault, however, is hard to detect due to the special fields of photovoltaic systems: constant direct current without zerocrossing point, sophisticated components leading to noise interruption, and usually occupying large area. Therefore, detectable characteristics are of great impo...

متن کامل

Using Pv Module and Line Frequency Response Data to Create Robust Arc Fault Detectors

Photovoltaic (PV) systems have caused residential and commercial building fires when an electrical arc fault initiates in the conduction path. Article 690.11 in the United States 2011 National Electrical Code requires new photovoltaic systems on or penetrating a building to include a listed arc fault protection device to prevent additional fires. In response, manufacturers are creating arc faul...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013