Effect of DC biasing in 3-legged 3-phase transformers taking detailed model of off-core path into account
نویسندگان
چکیده
modeling of 3-legged, 3-phase transformers under DC biasing is a challenging topic due to the need to have an adequate representation of flux paths beyond the active part including the tank. The main contribution of this paper is to present a new dual circuit model which takes the off—core flux path into consideration. An equivalent circuit is developed for this off-core path including equivalent non-linear branches for the tank elements. The adequacy of the proposed method is verified through zero sequence impedance tests at steady state. Having the new model, the behavior of a test transformer is studied under DC excitation in terms of magnetization current, reactive and active power flowing through the transformer.
منابع مشابه
Impacts of New Suggested Ferroresonance Limiter on the Stability Domain of Ferroresonance Modes in Power Transformers Considering Metal Oxide Surge Arrester Effect
this work studies the effect of neutral earth resistance on the controlling ferroresonance oscillation in the power transformer including MOV surge arrester. A simple case of ferroresonance circuit in a three phase transformer is used to show this phenomenon and the three-phase transformer core structures including nonlinear core losses are discussed. The effect of MOV surge arrester and neutra...
متن کاملA Bidirectional DC-DC Convreter with Zero Voltage Switching Capability for Energy Storage Application
In this paper, a bidirectional DC-DC converter with high power density for energy storage application is proposed. The presented converter provides power transfer in both directions only with adjusting phase shift angle. Zero voltage switching (ZVS) in both turn on and turn off moments of all switches is the major capability of the converter that makes it suitable for high power applications. Z...
متن کاملThermal model of oil power transformers with a tap changer
The paper presents a new method for on-line temperature calculation taking into account change in the tap changer position. The method introduces accurate calculation of the losses, depending on the current, average temperature of the winding, and tap changer position (it affects both Joules (DC) losses and stray losses). The thermal model itself is the common three-body model (for a transforme...
متن کاملDetermination of a new model to study ultra-saturation phenomenon during the loaded power transformer energization and its effect on differential protection
One of transient phenomenon that causes the mal-operation of the power transformer differential protection during the energization of a loaded power transformer is the ultra-saturation phenomenon. In this paper, a new model for investigating the ultra-saturation phenomenon during the energization of a loaded power transformer is presented and its effect on the differential protection of the pow...
متن کاملDetermination of a new model to study ultra-saturation phenomenon during the loaded power transformer energization and its effect on differential protection
One of transient phenomenon that causes the mal-operation of the power transformer differential protection during the energization of a loaded power transformer is the ultra-saturation phenomenon. In this paper, a new model for investigating the ultra-saturation phenomenon during the energization of a loaded power transformer is presented and its effect on the differential protection of the pow...
متن کامل