Comparison of air-displacement plethysmography with hydrostatic weighing and bioelectrical impedance analysis for the assessment of body composition in healthy adults.

نویسندگان

  • R R Biaggi
  • M W Vollman
  • M A Nies
  • C E Brener
  • P J Flakoll
  • D K Levenhagen
  • M Sun
  • Z Karabulut
  • K Y Chen
چکیده

BACKGROUND Over the past decade, considerable attention has been paid to accurately measuring body composition in diverse populations. Recently, the use of air-displacement plethysmography (AP) was proposed as an accurate, comfortable, and accessible method of body-composition analysis. OBJECTIVE The purpose of this study was to compare measurements of percentage body fat (%BF) by AP and 2 other established techniques, hydrostatic weighing (HW) and bioelectrical impedance analysis (BIA), in adults. DESIGN The sample consisted of healthy men (n = 23) and women (n = 24). %BF was measured by AP, HW, and BIA. RESULTS In the total group, %BF(AP) (25.0+/-8.9%) was not significantly different from %BF(HW) (25.1+/-7.7%) or %BF(BIA) (23.9+/-7.7%), and %BF(AP) was significantly correlated with %BF(HW) (r = 0.944, P < 0.001) and with %BF(BIA) (r = 0.859, P < 0.01). Compared with HW, AP underestimated %BF in men (by -1.24+/-3.12%) but overestimated %BF in women (by 1.02+/-2.48%), indicating a significant sex effect (P < 0.05). The differences in estimation between AP and BIA and between BIA and HW were not significantly different between the sexes. CONCLUSION AP is an accurate method for assessing body composition in healthy adults. Future studies should assess further the cause of the individual variations with this new method.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Muscle Mass, Total Body Water and Total Body Protein in Type II Diabetics with Healthy Matched Adults by Bioelectrical Impedance Analysis

Background: Bioelectrical impedance analysis (BIA) is a new and rapid technique to validate body composition. Several studies have used this technique to evaluate body compositions, such as muscle mass, in diabetic patients, but the results are very different. This may due the differences between diabetic patients and control group. Therefore, this study aimed to compare the muscle mass of diab...

متن کامل

Comparison of Total Fat, Percentage of Fat, Trunk Fat, Soft Lean and Mass Waist-Hip Ratio between Diabetic type II and Matched Non-Diabetic Iranians using Bioelectrical Impedance Analysis

Introduction: Research shows a relationship between diabetes (type II) and obesity. Bioelectrical Impedance Analysis (BIA) is a relatively new and approved method for the measurement of body composition. The aim of this study was to compare diabetic and non-diabetic adults on the basis of waist-hip ratio, total fat, percentage of fat, trunk fat, and soft lean mass. Methods: In this cross-sec...

متن کامل

Air Displacement Plethysmography versus Dual-Energy X-Ray Absorptiometry in Underweight, Normal-Weight, and Overweight/Obese Individuals

BACKGROUND Accurately estimating fat percentage is important for assessing health and determining treatment course. Methods of estimating body composition such as hydrostatic weighing or dual-energy x-ray absorptiometry (DXA), however, can be expensive, require extensive operator training, and, in the case of hydrostatic weighing, be highly burdensome for patients. Our objective was to evaluate...

متن کامل

Evaluation of Hand-to-Hand Bioelectrical Impedance Analysis for Estimating Percent Body Fat in Young Adults

Purposes were to (a) to examine the validity and precision of a hand-to-hand bioelectrical impedance analyzer (HBIA) and (b) to determine the effect of an acute sub-maximal aerobic exercise bout on HBIA percent body fat (%BF) measures. Forty-one young adults (21 women; 20 men) visited the laboratory for body composition assessment on two separate occasions. During the control session, %BF was a...

متن کامل

The Impact of Feet Callosities, Arm Posture, and Usage of Electrolyte Wipes on Body Composition by Bioelectrical Impedance Analysis in Morbidly Obese Adults

OBJECTIVE This study evaluated the impact of feet callosities, arm posture, and use of electrolyte wipes on body composition measurements by bioelectrical impedance analysis (BIA) in morbidly obese adults. METHODS 36 morbidly obese patients (13 males, aged 28-70 years, BMI 41.6 ± 4.3 kg/m2) with moderate/severe feet callosities participated in this study. Body composition (percent body fat (%...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The American journal of clinical nutrition

دوره 69 5  شماره 

صفحات  -

تاریخ انتشار 1999