Detection of patent coronary bypass grafts by computed tomography. A preliminary report.
نویسندگان
چکیده
Twenty-three coronary bypass graft patients were evaluated by a contrast-enhanced computed tomography (CT) technique to determine graft patency. Four to six 4.8-second sequenced scans with a 1-second interscan interval were obtained in each patient during the hand injection of 25-30 ml of contrast medium in a peripheral vein. Patency of grafts was determined by a characteristic contrast enhancement. The CT technique correlated with angiographic assessment of graft patency in 59 of 62 grafts (95%). We conclude that this relatively noninvasive technique shows promise as a method for determining coronary bypass graft patency.
منابع مشابه
Aortic valve replacement after previous coronary artery bypass grafting: a case report.
We experienced a case of aortic valve replacement after previous coronary artery bypass grafting with patent bypass grafts. Based on the retrosternal anatomy assessed by preoperative angiography and thoracic computed tomography, aortic valve replacement was performed through a median resternotomy. After careful dissection of the right side of the heart and the ascending aorta, cardiopulmonary b...
متن کاملEvaluation of early coronary graft patency after coronary artery bypass graft surgery using multislice computed tomography angiography
BACKGROUND Coronary artery bypass graft (CABG) surgery is the standard of care in the treatment of advanced coronary artery disease, and its long-term results are affected by the failure of bypass grafts. The aim of the present study was to evaluate the early patency rate in coronary bypass grafts. METHODS A total of 107 consecutive patients who underwent CABG were included in this study. Ear...
متن کاملDiagnostic accuracy of noninvasive coronary angiography in patients after bypass surgery using 64-slice spiral computed tomography with 330-ms gantry rotation.
BACKGROUND Multidetector computed tomographic angiography (MDCT) has been shown to allow detection of coronary artery bypass graft (CABG) occlusions and stenoses. However, the assessment of native coronary arteries in addition to CABG has thus far not been sufficiently validated. METHODS AND RESULTS Fifty patients with a total of 138 CABG (34 mammary grafts, 3 radial grafts, 101 venous grafts...
متن کاملValue and limitations of computed tomography in assessing aortocoronary bypass graft patency.
To determine the value of nondynamic computed tomography (CT) in assessing aortocoronary bypass graft patency, we studied 67 patients with 125 grafts by CT and by coronary angiography at close time intervals. CT scans were performed before and after one to three (average 1.98 +/- 0.65) 50-ml i.v. bolus injections of contrast material. Eighty-four of 92 grafts patent at angiography were also vis...
متن کاملNoninvasive evaluation of coronary artery bypass grafts with 16-slice multidetector computed tomography.
BACKGROUND The aim of this study was to investigate the diagnostic accuracy of 16-slice multislice, multidetector computed tomography (MDCT) angiography for the evaluation of grafts in patients with coronary artery bypass grafting (CABG). METHODS Fifty-eight consecutive patients with CABG who underwent both MDCT and conventional invasive coronary angiography were included. The median time int...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation
دوره 61 4 شماره
صفحات -
تاریخ انتشار 1980