Quantification of right-to-left shunt with (99m)Tc-labelled albumin macroaggregates and 100% oxygen in patients with hereditary haemorrhagic telangiectasia.

نویسندگان

  • Johannes J Mager
  • Pieter Zanen
  • Fred Verzijlbergen
  • Cornelius J J Westermann
  • Tjeerd Haitjema
  • Gerard van Herk
  • Jan-Willem J Lammers
چکیده

Pulmonary arteriovenous malformations (PAVMs) are often associated with hereditary haemorrhagic telangiectasia (HHT). The quantification of right-to-left shunts in patients with PAVMs is important in diagnosis and follow up. Traditionally, this shunt is measured by the 100% oxygen method, in which the value for the arteriovenous difference in oxygen content, Cao(2)-CVO(2) (where Cao(2) is the oxygen content of arterial blood and CVO(2) is the oxygen content of mixed venous blood) is estimated. Alternative methods consist of measurement of the systemic or renal uptake of (99m)Tc-labelled macroaggregates of albumin (MAA), which are trapped in pulmonary capillaries, but pass through PAVMs. We first measured Cao(2)-CVO(2) in 12 HHT patients before and after embolization of PAVMs. We obtained a mean value of 4.4 ml/100 ml, instead of the usual 5 ml/100 ml. Subsequently, we measured right-to-left shunt in 21 HHT patients using the 100% oxygen method and with two different methods involving (99m)Tc. We used the kidney-lung method (K/L method), in which it is assumed that the right kidney receives 10% of the cardiac output, and we also used a method with two tracers (HSA/MAA method): (1) (99m)Tc-labelled human serum albumin (HSA) (which passes through pulmonary capillaries) to measure the fraction of the cardiac output perfusing the kidneys, and (2) MAA to measure the shunt fraction. In 35 shunt measurements we evaluated this new technique and the K/L method, by comparing the results with those from the 100% oxygen method. There was poor agreement between the 100% oxygen method and the K/L method, with 95% limits of agreement for the shunt fraction of -15.2% to +15.2%. There was moderate agreement between the 100% oxygen method and the HSA/MAA method, with limits of agreement of -8.3% to +7.7%. We conclude that the different methods cannot replace each other, because the limits of agreement are too wide for clinical use.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pulmonary shunt fraction measurement compared to contrast echocardiography in hereditary haemorrhagic telangiectasia patients: time to abandon the 100% oxygen method?

BACKGROUND The presence of pulmonary right-to-left shunting (RLS) is associated with severe neurological complications from paradoxical embolisation in patients with hereditary haemorrhagic telangiectasia (HHT) and screening is warranted. Pulmonary shunt fraction measurement with the 100% oxygen method can be used for the detection and quantification of functional pulmonary RLS, although transt...

متن کامل

Reproducibility of right-to-left shunt quantification using transthoracic contrast echocardiography in hereditary haemorrhagic telangiectasia

AIM Transthoracic contrast echocardiography (TTCE) is recommended for screening of pulmonary arteriovenous malformations (PAVMs) in hereditary haemorrhagic telangiectasia. Shunt quantification is used to find treatable PAVMs. So far, there has been no study investigating the reproducibility of this diagnostic test. Therefore, this study aimed to describe inter-observer and inter-injection varia...

متن کامل

Sensitivity and specificity of radioisotope right-left shunt measurements and pulse oximetry for the early detection of pulmonary arteriovenous malformations.

STUDY OBJECTIVES To assess the effectiveness of pulse oximetry and radioisotope measurement of right-to-left (R-L) shunt for the early detection of pulmonary arteriovenous malformations (PAVMs) in patients with hereditary hemorrhagic telangiectasia (HHT). DESIGN Patients with HHT had serial measurements of the following: (1) arterial oxygen saturation (SaO2) by pulse oximetry in erect and sup...

متن کامل

Contrast Enhanced Echocardiography for Detection of Intrapulmonary Shunts in Liver Transplant Candidates

Background: Intrapulmonary vascular abnormalities associated with liver cirrhosis may result in intrapulmonary right-to-left shunt and hypoxemia. The aim of this study was to use contrast enhanced echocardiography to detect intrapulmonary vascular abnormalities in patients with liver cirrhosis candidates for liver transplantation. Methods: One hundred and two adult patients underwent contrast e...

متن کامل

Comparison of Tc-99m Ethylenedicysteine (Tc-99m EC) with Tc-99m DPTA in evaluation of renal disease [Persian]

Tc-99m-EC is a new renal radiopharmaceutical introduced as an alternative for Tc-99m MAG3. Twenty-three normal volunteers and patients in different .stages of renal disease were evaluated with Te-99m EC and Tc-99m DTPA. The mean initial uptake of EC was significantly higher as compared to DTPA. There was a high correlation between rectangular and hand-drawn ROls for kidney and background,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical science

دوره 102 2  شماره 

صفحات  -

تاریخ انتشار 2002