Field evaluation of the Copal UA-231 automatic sphygmomanometer.
نویسندگان
چکیده
Automated sphygmomanometers should be evaluated in field studies before being recommended for epidemiological use. In this study an automated sphygmomanometer, the Copal UA-231, was evaluated on the basis of duplicate blood pressure measurements, one with this machine and one with a Hawksley random zero machine, taken on 1536 participants in a health survey. The Copal-random zero differences had a mean of 2.3 mm Hg for systolic blood pressure and 1.9 mm Hg for diastolic pressure, the Copal reading higher than the random zero. The standard deviations of these differences were similar to the standard deviations of the differences between two random zero measurements taken on subjects in a separate survey. However, Copal-random zero differences varied systemically with blood pressure levels. In this study a 10 mm Hg increase in systolic blood pressure was associated with a 1.22 mm Hg increase in the Copal-random zero difference and a 10 mm Hg increase in diastolic blood pressure was associated with a 1.15 mm Hg increase in the Copal-random zero difference. The Copal UA-231 is recommended for use in field surveys, but it should be recognised that a small systematic increase in Copal-random zero difference with increasing blood pressure may complicate interpretation of epidemiological associations.
منابع مشابه
Automatic measurement of blood pressure: evaluation of the Copal UA-231 automatic sphygmomanometer.
The suitability of an automatic sphygmomanometer for epidemiological work was evaluated in two studies. In the first, blood pressure measurements were made alternately on the automatic machine and on a Hawksley random zero instrument on 14 volunteers on each of four consecutive days by a single medical observer. No significant difference was found between the mean diastolic pressure obtained by...
متن کاملAgreement between the Takeda UA-731 automatic blood pressure measuring device and the manual mercury sphygmomanometer: an assessment under field conditions in Newcastle upon Tyne, UK.
STUDY OBJECTIVE To assess agreement between two Takeda UA-731 automatic blood pressure measuring devices (referred to as machines A and B) and two manual mercury sphygmomanometers. DESIGN A 'Y' connector attached each Takeda UA-731 to a manual mercury sphygmomanometer. Simultaneous measurements were made on adult subjects. SETTING A population based cardiovascular disease survey in Newcastl...
متن کاملFormulation and In Vitro Evaluation of Extended Release Tablets of Paliperidone Using Natural Gums
Paliperidone is a well known dopamine antagonist of the atypical antipsychotic class. In the present study Paliperidone was formulated as ER release tablets using natural and synthetic polymers separately or in combination. The aim of ER release formulation is to reduce the frequency of dosing. Tablets are prepared by direct compression method. The optimized formulations contain Paliperidone as...
متن کاملAutomatic keyword extraction using Latent Dirichlet Allocation topic modeling: Similarity with golden standard and users' evaluation
Purpose: This study investigates the automatic keyword extraction from the table of contents of Persian e-books in the field of science using LDA topic modeling, evaluating their similarity with golden standard, and users' viewpoints of the model keywords. Methodology: This is a mixed text-mining research in which LDA topic modeling is used to extract keywords from the table of contents of sci...
متن کاملTags Re-ranking Using Multi-level Features in Automatic Image Annotation
Automatic image annotation is a process in which computer systems automatically assign the textual tags related with visual content to a query image. In most cases, inappropriate tags generated by the users as well as the images without any tags among the challenges available in this field have a negative effect on the query's result. In this paper, a new method is presented for automatic image...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of epidemiology and community health
دوره 42 4 شماره
صفحات -
تاریخ انتشار 1988