DNA damage detection technique applying time-resolved fluorescence measurements.

نویسندگان

  • Gonzalo Cosa
  • Anne L Vinette
  • J R N McLean
  • J C Scaiano
چکیده

A novel DNA damage detection technique based on the characteristic fluorescence lifetimes exhibited by Pico-Green-single-stranded DNA and -double-stranded DNA complexes is employed to establish the damage produced on DNA isolated from sheep white blood cells following gamma radiation. This technique, which incorporates key concepts such as alkaline unwinding buffers and higher unwinding rates of damaged DNA compared to undamaged DNA, allows for the differentiation of DNA damage resulting from doses of gamma radiation in the 0-100-Gy range, with the potential of analyzing samples consisting of as little as 10(4) cells. Experiments were carried out using commercial DNA sources as well as DNA isolated from sheep white blood cells, suggesting its potential for use with isolated DNA from virtually any eukaryotic cell.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Time-resolved fluorescence detection of enzyme-amplified lanthanide luminescence for nucleic acid hybridization assays.

A new nonisotopic detection method based on time-resolved fluorescence for nucleic acid hybridization assays with alkaline phosphatase labels has been developed: enzyme-amplified lanthanide luminescence (EALL). EALL combines the amplification of an enzyme label with the sensitivity and background elimination of time-resolved fluorescence detection of lanthanide ion luminescence. The detection s...

متن کامل

Ultrafast solvent dynamics: Connection between time resolved fluorescence and optical Kerr measurements

Articles you may be interested in Advances in ultrafast time resolved fluorescence physics for cancer detection in optical biopsy Polar solvation dynamics of coumarin 153 by ultrafast time-resolved fluorescence Orientational and interaction induced dynamics in the isotropic phase of a liquid crystal: Polarization resolved ultrafast optical Kerr effect spectroscopy The effects of anion and catio...

متن کامل

CMOS Time-Resolved, Contact, and Multispectral Fluorescence Imaging for DNA Molecular Diagnostics

Instrumental limitations such as bulkiness and high cost prevent the fluorescence technique from becoming ubiquitous for point-of-care deoxyribonucleic acid (DNA) detection and other in-field molecular diagnostics applications. The complimentary metal-oxide-semiconductor (CMOS) technology, as benefited from process scaling, provides several advanced capabilities such as high integration density...

متن کامل

A homogeneous europium cryptate-based assay for the diagnosis of mutations by time-resolved fluorescence resonance energy transfer.

Oligonucleotide ligation assay (OLA) is considered to be a very useful methodology for the detection and characterization of mutations, particularly for clinical purposes. The fluorescence resonance energy transfer between a fluorescent donor and a suitable fluorophore as acceptor has been applied in the past to several scientific fields. This technique is well adapted to nucleic acid analysis ...

متن کامل

Validation and evaluation of a novel time-resolved laser-induced fluorescence technique.

We present a novel technique to measure time-resolved laser-induced fluorescence signals in plasma sources that have a relatively constant Fourier spectrum of oscillations in steady-state operation, but are not periodically pulsed, e.g., Hall thrusters. The technique uses laser modulation of the order of MHz and recovers signal via a combination of band-pass filtering, phase-sensitive detection...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 74 24  شماره 

صفحات  -

تاریخ انتشار 2002