Performance Evaluation and Strengthening of Deficient Beam-Column Sub-assemblages under Cyclic Loading
نویسنده
چکیده
منابع مشابه
Seismic behavior of drilled beam section in moment connections
Abstract: Reduced Beam Section (RBS) and Drilled Beam Section (DBS) are seismic moment resistant frame connections, introduced after 1994 Northridge earthquake. RBS connection has been tested under cyclic loading and showed acceptable performance. In this paper, seismic behavior of Drilled Beam Section (DBS) connection is studied numerically using finite element method. A drilled beam section ...
متن کاملCyclic and Monotonic Behavior of Strengthened and Unstrengthened Square Reinforced Concrete Columns
The use of composite materials is an effective technique to enhance the capacity of reinforced concrete columns subjected to the seismic loading due to their high tensile strength. In this paper, numerical models are developed in order to predict the experimental behavior of square reinforced concrete columns strengthened by glass fiber reinforced polymer and steel bars and unstrengthened colum...
متن کاملEvaluation of Column-Tree Moment Resisting Connection with End Plates and Haunched Beam (RESEARCH NOTE)
The column-tree constructional schemes allows for a reliable and convenient erection of moment resisting steel frames. Strengthening of column-tree connection with a haunch part can significantly improve seismic behavior of whole system. In the current study behavior of column-tree connections with haunched beams and end plate splices have been investigated. Special attention was paid for evalu...
متن کاملAnalytical and Experimental Investigation of I Beam-to-CFT Column Connections under Monotonic Loading (RESEARCH NOTE)
In this study, the behavior characteristics of I beam-to-concrete filled tube (CFT) column connection is studied through experiment and finite element models under the monotonic loading. To validate the finite element modeling, at first, an experimental model is made and experimented. After validation of the finite element modeling, different models were created in the software. The studied par...
متن کاملPerformance of the Modified Precast Beam to Column Connection Placed on a Concrete Corbel
Precast concrete structures in Iran are generally designed as continuous columns with hinged beams, thereby making them simple frames. In this system in site show walls in two directions of buildings guaranteed lateral resisting system. However, in order to obtain a seismic resisting frame, the connection between beam and column should be moment resisting and ductile, allowing the formation of ...
متن کامل