Anesthesia for intraoperative neurophysiologic monitoring of the spinal cord.

نویسندگان

  • Tod B Sloan
  • Eric J Heyer
چکیده

Intraoperative neurophysiologic monitoring (INM) using somatosensory and motor evoked potentials (MEPs) has become popular to reduce neural risk and to improve intraoperative surgical decision making. Intraoperative neurophysiologic monitoring is affected by the choice and management of the anesthetic agents chosen. Because inhalational and intravenous anesthetic agents have effects on neural synaptic and axonal functional activities, the anesthetic effect on any given response will depend on the pathway affected and the mechanism of action of the anesthetic agent (i.e., direct inhibition or indirect effects based on changes in the balance of inhibitory or excitatory inputs). In general, responses that are more highly dependent on synaptic function will have more marked reductions in amplitude and increases in latency as a result of the synaptic effects of inhalational anesthetic agents and similar effects at higher doses of intravenous agents. Hence, recording cortical somatosensory evoked potentials and myogenic MEPs requires critical anesthetic choices for INM. The management of the physiologic milieu is also important as central nervous system blood flow, intracranial pressure, blood rheology, temperature, and arterial carbon dioxide partial pressure produce alterations in the responses consistent with the support of neural functioning. Finally, the management of pharmacologic neuromuscular blockade is critical to myogenic MEP recording in which some blockade may be desirable for surgery but excessive blockade may eliminate responses. A close working relationship of the monitoring team, the anesthesiologist, and the surgeon is key to the successful conduct and interpretation of INM.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intraoperative neurophysiologic monitoring during spinal surgery.

Intraoperative neurophysiologic monitoring (IONM) is a battery of neurophysiologic tests used to assess the functional integrity of the spinal cord, nerve roots, and other peripheral nervous system structures (eg, brachial plexus) during spinal surgery. The underlying principle of IONM is to identify emerging insult to nervous system structures, pathways, and/or related vascular supply and to p...

متن کامل

Potential neurological risk during a titanium rib procedure and appropriate intraoperative neurophysiologic monitoring modalities.

The titanium rib procedure is a safe and effective way of surgically treating pediatric patients with thoracic insufficiency syndrome and scoliosis. As with any invasive surgical procedure, it is not without risks. This article explains the potential risks to neurological structures while outlining the surgical approach and the neurological anatomy in the vicinity of the implanted instrumentati...

متن کامل

An approach to intraoperative neurophysiologic monitoring of thoracoabdominal aneurysm surgery.

Thoracoabdominal aneurysm surgery carries an approximate 10% risk of intraoperative paraplegia. Abrupt cord ischemia and the confounding effects of systemic alterations and limb or cerebral ischemia challenges neurophysiologic spinal cord monitoring. This investigation sought a rapid differential monitoring approach to predict or help prevent paraplegia. Thirty-one patients were monitored with ...

متن کامل

Intraoperative monitoring for spinal radiculomedullary artery aneurysm occlusion treatment: What, when, and how long?

BACKGROUND Spinal radiculomedullary artery aneurysms are extremely rare. Treatment should be tailored to clinical presentation, distal aneurysm flow, and lesion anatomical features. When a surgical occlusion is planned, it is necessary to evaluate whether intraoperative monitoring (IOM) should be considered as an indispensable tool to prevent potential spinal cord ischemia. METHODS We present...

متن کامل

Highlights of anesthetic considerations for intraoperative neuromonitoring.

Though relatively new, intraoperative neurophysiological monitoring (IONM) has become standard of care for many neurosurgical procedures. The use of IONM has substantially decreased the rate of paralysis after deformity surgery, and has been validated in cervical spine surgery, and thoracic and lumbar laminectomy (1) (2), (3). The main modalities are: somatosensory evoked potentials (SSEPs), mo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society

دوره 19 5  شماره 

صفحات  -

تاریخ انتشار 2002