Comparison of the rebuilding effects of different computed tomography scanners and reconstructive settings for the five-line sign in normal interlobular fissures
نویسندگان
چکیده
Background: Based on the images generated from two multi-slice computed tomography (CT) scanners, we intended to compare the five-line sign of normal interlobular fissures produced on axial or oblique maximum intensity projection (MIP) reconstructions using different algorithms. Methods: Two groups of 50 subjects underwent either 16-slice or 256-slice spiral unenhanced chest CT. None of them in either group displayed any abnormality. For each case, maximum intensity projection (MIP) data were used to calculate the axial or oblique projection using four algorithms: standard axial, standard oblique, high-resolution axial, and high-resolution oblique algorithm. The results were then used to reconstruct images of six locations of the lung. The clarity of the five-line sign of the reconstructed MIPs for the interlobular fissures was determined and graded as 1 (unclear), 2 (barely clear), or 3 (clear). Comparisons of the rate and the degree of clarity were performed using nonparametric tests. Results: Data from both the 16-slice and 256-slice CT revealed that the standard oblique algorithm was the best among the four methods for presenting clear images of the five-line sign (p < 0.001), whereas the high-resolution axial algorithm was the worst. In addition, the two CT units exhibited no significant differences in the clarity of the five-line sign (p = 0.273). Conclusions: The standard oblique algorithm was the best approach to reveal the five-line sign of normal lung fissures. Both 16-slice and 256-slice CT were effective for reconstructing the sign.
منابع مشابه
Validation of computed tomography-based attenuation correction of deviation between theoretical and actual values for four computed tomography scanners
Objective: In this study, we aimed to validate the accuracy of computed tomography-based attenuation correction (CTAC) using the bilinear scaling method.Methods: The measured attenuation coefficient (μm) was compared to a theoretical attenuation coefficient (μt ) using four different CT scanners and an RMI 467 phantom. The effective energy of the CT beam X-rays was calculated, using the aluminu...
متن کاملSectional Anatomy Quiz - V
In this series a pictorial quiz pertaining to identification of normal anatomical structures and landmarks at a given level on the computed tomography (CT) is presented. An image depicting normal anatomy is followed by a series of images showing different pathologies. Readers are expected to identify and appreciate variation and changes in the normal anatomy in presence of a given pathology. Th...
متن کاملDose Reduction Methods in Chest Computed Tomography
Introduction: Computed tomography is one of the most powerful tools for investigating thorax disease, because it shows progression of lung disease much clearer than chest radiography. Technical advances in CT scanners have led to some abilities for CT scanners such as coverage of larger volume, lower noise and ability for acquiring image in one respiratory phase. However, this will be accompani...
متن کاملDosimetry of Critical Organs in Maxillofacial Imaging with Cone-beam Computed Tomography
Background: While the benefits of cone-beam computed tomography (CBCT) are well known in maxillofacial imaging, the use of this modality is not risk-free.Objective: The aim of this study was to evaluate the exposure doses received by patients during maxillofacial imaging with CBCT.Methods: Entrance surface dose (ESD) was measured by using thermoluminescent dosimeters (TLDs) attached to the eyes...
متن کاملApplication of Different methods for Reducing Radiation Dose to Breast during MDCT
The increased use of computed tomography (CT) and its high radiation dose have led to great concerns about its potential for radiation induced cancer risks. Breast is a radiosensitive tissue based on tissue weighting factors assigned by the International Commission on Radiological Protection (ICRP). Moreover, the dose is maximal on the surface of the patient. Therefore, strategies should be tak...