Improved survival of thalassaemia major in the UK and relation to T2* cardiovascular magnetic resonance
نویسندگان
چکیده
BACKGROUND The UK Thalassaemia Register records births, deaths and selected clinical data of patients with thalassaemia who are resident in the UK. A study of survival and causes of death was undertaken which aimed to include the possible impact of T2* cardiovascular magnetic resonance (CMR). METHODS The Register was updated to the end of 2003, copies of death certificates were obtained, and causes of death in beta thalassaemia major were extracted. In addition, patients who had T2* CMR assessment of cardiac iron load and/or received the oral iron chelator deferiprone were identified from clinical records. RESULTS The main causes of death were anaemia (before 1980), infections, complications of bone marrow transplantation and cardiac disease due to iron overload. From 1980 to 1999 there were 12.7 deaths from all causes per 1,000 patient years. Forty per cent of patients born before 1980 had T2* cardiovascular magnetic resonance between 2000 and 2003, and 36% of these patients were prescribed deferiprone before end of 2003. In 2000-2003, the death rate from all causes fell significantly to 4.3 per 1,000 patient years (-62%, p < 0.05). This was mainly driven by the reduction in the rate of deaths from iron overload which fell from 7.9 to 2.3 deaths per 1,000 patient years (-71%, p < 0.05). CONCLUSION Since 1999, there has been a marked improvement in survival in thalassaemia major in the UK, which has been mainly driven by a reduction in deaths due to cardiac iron overload. The most likely causes for this include the introduction of T2* CMR to identify myocardial siderosis and appropriate intensification of iron chelation treatment, alongside other improvements in clinical care.
منابع مشابه
Evaluation of tissue doppler echocardiography and T2* magnetic resonance imaging in iron load of patients with thalassemia major
Background: Iron-mediated cardiomyopathy is the main complication of thalassemia major (TM) patients. Therefore, there is an important clinical need in the early diagnosis and risk stratification of patients. The aim of this study was to evaluate the efficacy of tissue doppler imaging (TDI) to study cardiac iron overload in patients with TM using T2* magnetic resonance (MR) as the gold-standard...
متن کاملAssessment of Organ Specific Iron Overload in Transfusion-dependent Thalassemia by Magnetic Resonance Imaging Techniques
The consequence of repeated blood transfusions in thalassemia is iron overload in different organs. Magnetic resonance imaging (MRI) is a reliable, non-invasive and accurate method for iron detection in various tissues, hence the introduction of MRI has revolutionized the management of these patients and improved the life expectancy of them. Cardiac MRI T2* has a profound effect not only on est...
متن کاملComparison of Magnetic Resonance Imaging T2 Results in Beta-Thalassemia Patients Treated by Deferasirox or Combination of Deferoxamine and Deferiprone
Background: Iron extra load is an anticipated and lethal consequence of chronic blood transfusion in major beta-thalassemia patients; therefore it is necessary to use an efficient iron chelator drug to stimulate the evacuation of the surplus iron from the body. This trial was performed to compare myocardial and hepatic magnetic resonance imaging T2 (MRI T2*) results of beta-thalassemia patients...
متن کاملRelation of myocardial T2* to right ventricular function in thalassaemia major.
AIMS Myocardial T2* cardiovascular magnetic resonance (CMR) provides a rapid and reproducible measure of cardiac iron loading and is being increasingly used worldwide for monitoring of transfusion-dependent thalassaemia patients. Although myocardial siderosis (T2* <20 ms) is associated with impaired left ventricular (LV) function, little is known of its relation with right ventricular (RV) func...
متن کاملMagnetic resonance imaging of feline eye
The purpose of this study was to investigate magnetic resonance imaging (MRI) of the normal feline eyeand optic nerves using T1-weighted and T2-weighted images. A total of 6 healthy female domestic short haircats age 2-2.5 years and weighing 3.2 ± 0.4 kg were selected. Magnetic resonance imaging data werecollected using GEMSOW (Philips) at a magnetic field strength of 1.5 T. Dorsal, sagittal, a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of Cardiovascular Magnetic Resonance
دوره 10 شماره
صفحات -
تاریخ انتشار 2008