Morphological Changes in Oral Mucosa of Rabbits Induced by Light Emitting Diode (led) Used as Dental Curing Light
نویسندگان
چکیده
A dental curing light is a piece of dental tool that is used for the hardening of light cure composites. Many studies have shown these lights induce changes in DNA, mitosis and mitochondria through free radicals production. Light emitting diode (LED) are most commonly used and claim less hazards to the adjacent soft tissues. Current study was therefore designed to observe the morphological changes induced by light emitting diode (LED) as a dental curing light source in oral mucosa of experimental animals. Fifty rabbits were divided into 5 groups (4 experimental and 5th as a control group). Cervical margin of central incisors of each animal in the experimental groups was exposed 3 times with LED light; duration of each exposure being 40 seconds with a gap of 30 seconds. Punch biopsies were taken after 24 hours, 48 hours, 1week and 2weeks from group 1, 2, 3 and 4 animals respectively. Results showed ulceration (4%), acanthosis and vascular pathological changes (100%), enlarge (bulbous) rete ridges (97.5%), basal layer vacuolization (85%), acantholysis (27.5%) and atypical mitosis (10%) in all the experimental animals. With passage of time, a significant increase (P=0.000) in frequency of basal cell hyperplasia (90% in group 1 to 100% in group 4) and basal layer atypia (70% in group 1 to 90% in group 4) was observed. While inflammation dropped from 100% in group 1 to 0% in group 4 (P=0.000) due to healing of tissues. Changes were similar to the previous studies except some severe effects like atypical mitosis and basal layer atypia were observed which may be attributed to increase in number of light exposures in our study that is in compliance with the clinical practice in our set up. These findings may help in creating awareness among the dental practitioners to use dental curing lights with caution keeping appropriate safety measures for the adjacent oral soft tissue in consideration.
منابع مشابه
Comparative evaluation of the effect of Light Emitting Diode (LED) and Quartz Tungsten Halogen (QTH) light curing units on color stability of Filtek Z350 XT
Introduction:Discoloration of the resin-based composites is a common problem in restorative dentistry. There are many factors associated with the discoloration of dental materials in the oral environment. The purpose of this study was to evaluate the color changes in a nano-composite cured with a quartz-tungsten-halogen (QTH) and light emitting diode (LED) unit. Methods:80 disk-shaped specim...
متن کاملEvaluation of the Effect of Protective Sleeve on Output Intensity of Light Emitting Diode Light Cure Units
Aim: The purpose of this study was to compare the difference in the output intensity of Light Emitting Diode (LED) light cure (LC) devices with and without a protective sleeve and its clinical significance. Materials and Methods: The output intensity of 152 LC units in dental offices across the state of Odisha were examined. The collection of related information included an average number of e...
متن کاملThe Effect of Standard and Extended Curing Time in Different Distances on Composite’s Degree of Conversion
Introduction: The aim of this study was to in-vestigate the effect of irradiation duration and distance of light tip to prepared samples in two different light curing unites on the degree of conversion of resin composite. Materials and Methods: Conventional halogen and blue Light emitting diode (LED) units were used for polymerization of an Opalis resin com-posite. The conversion measurements w...
متن کاملA comparative evaluation of curing depth and compressive strength of dental composite cured with halogen light curing unit and blue light emitting diode: an in vitro study.
PURPOSE To evaluate the curing depth and compressive strength of dental composite using halogen light curing unit and light emitting diode light curing unit. MATERIALS AND METHODS Eighty cylindrical composite specimens were prepared using posterior composite P60(3M). Forty specimens, out of which 20 samples (group A) cured with halogen light and 20 samples (group B) cured using light emitting...
متن کاملCuring Efficacy of Light Emitting Diodes of Dental Curing Units
BACKGROUND AND AIMS The aim of the present study was to compare the efficacy of quartz tungsten halogen (QTH) and light emitting diode (LED) curing lights on polymerization of resin composite. MATERIALS AND METHODS A hybrid resin composite was used to prepare samples which were cured using two QTH and ten LED light curing sources. Twelve groups, each containing ten samples, were prepared usin...