Five-year follow-up after intracoronary gamma radiation therapy for in-stent restenosis.

نویسندگان

  • Ron Waksman
  • Andrew E Ajani
  • R Lawrence White
  • Rosanna Chan
  • Bill Bass
  • Augusto D Pichard
  • Lowell F Satler
  • Kenneth M Kent
  • Rebecca Torguson
  • Regina Deible
  • Ellen Pinnow
  • Joseph Lindsay
چکیده

BACKGROUND The Washington Radiation for In-Stent Restenosis Trial is a double-blinded randomized study evaluating the effects of intracoronary radiation therapy (IRT) in patients with in-stent restenosis (ISR). METHODS AND RESULTS One hundred thirty patients with ISR (100 native coronary and 30 vein grafts) underwent percutaneous transluminal coronary angioplasty, laser ablation, rotational atherectomy, or additional stenting (36% of lesions). Patients were randomized to either 192-Iridium IRT or placebo, with a prescribed dose of 15 Gy to a 2-mm radial distance from the center of the source. Angiographic restenosis (27% versus 56%, P=0.002) and target vessel revascularization (26% versus 68%, P<0.001) were reduced at 6 months in patients treated with IRT. Between 6 and 60 months, patients treated with IRT compared with placebo had more target lesion revascularization (IRT, 21.6% versus placebo, 4.7%; P=0.04) and target vessel revascularization (IRT, 21.5% versus placebo, 6.1%; P=0.03). At 5 years, the major adverse cardiac event rate was significantly reduced with IRT (46.2% versus 69.2%, P=0.008). CONCLUSIONS In the Washington Radiation for In-Stent Restenosis Trial, patients with ISR treated with IRT using 192-Iridium had a reduction in the need for repeat target lesion and vessel revascularization at 6 months and 5 years.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Overview of Intracoronary Brachytherapy for in-Stent Restenosis of a Drug-Eluting Stent

Percutaneous coronary intervention with stenting is considered recently as the most common procedure for the treatment of symptomatic coronary. The article reviewed 41 studies published during 1997-2019 on intracoronary brachytherapy for in-stent restenosis of a drug-eluting stent. Intracoronary radiation therapy was finally confirmed in the setting of in-stent restenosis using as adjunctive th...

متن کامل

Cutting Balloon Angioplasty versus Conventional Balloon Angioplasty for In-Stent Restenosis Treated by Intracoronary Radiation Therapy

Background: Cutting Balloon angioplasty (CBA) may be a useful treatment modality for in-stent restenosis (ISR) as it maintains a stable position during dilatation and results in potentially less injury than plain old balloon angioplasty (POBA). The purpose of this study was to compare CBA and POBA with intracoronary radiation therapy (IRT) for in-stent restenosis (ISR). Methods: We selected 157...

متن کامل

Cost-effectiveness of gamma radiation for treatment of in-stent restenosis: results from the Gamma-1 trial.

BACKGROUND Recently, several randomized trials have demonstrated that intracoronary brachytherapy can reduce the rates of both angiographic and clinical restenosis in patients undergoing percutaneous coronary intervention (PCI) for in-stent restenosis. Whether this practice is cost-effective is unknown. METHODS AND RESULTS Between December 1997 and July 1998, 252 patients with in-stent resten...

متن کامل

Five-year clinical follow-up after intracoronary radiation: results of a randomized clinical trial.

BACKGROUND Several clinical trials indicate that intracoronary radiation is safe and effective for treatment of restenotic coronary arteries. We previously reported 6-month and 3-year clinical and angiographic follow-up demonstrating significant decreases in target lesion revascularization (TLR) and angiographic restenosis after gamma radiation of restenotic lesions. The objective of this study...

متن کامل

Late total occlusion after intracoronary brachytherapy for patients with in-stent restenosis.

OBJECTIVES The study sought to determine the incidence and predictors of late total occlusion (LTO, >30 days) in-patients with in-stent restenosis who were treated with intracoronary radiation. BACKGROUND Intracoronary radiation both with beta and gamma emitters has been shown to reduce recurrent in-stent restenosis. METHODS We reviewed the records of 473 patients who presented with in-sten...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 109 3  شماره 

صفحات  -

تاریخ انتشار 2004