Discrepancies between Doppler and catheter gradients in aortic prosthetic valves in vitro. A manifestation of localized gradients and pressure recovery.
نویسندگان
چکیده
To evaluate possible causes of discrepancy between Doppler and catheter gradients across prosthetic valves, five sizes (19-27 mm) of St. Jude and Hancock valves were studied in an aortic pulsatile flow model. Catheter gradients at multiple sites distal to the valve were compared with simultaneously obtained Doppler gradients. In the St. Jude valve, significant differences between Doppler and catheter gradients measured 30 mm downstream from the valve were found: Doppler gradients exceeded peak catheter gradients of 10 mm Hg or more by 81 +/- 35% (15 +/- 3.6 mm Hg), and mean catheter gradients by 71 +/- 11% (10.3 +/- 2.5 mm Hg). When the catheter was pulled back through the tunnel-like central orifice of the valve, high localized gradients at the valve plane and significant early pressure recovery were found. When the catheter was pulled back through the large side orifices, gradients at the same level were only 46 +/- 6% of the central orifice gradients (mean difference, 7.6 +/- 4.5 mm Hg). Doppler peak and mean gradients showed excellent agreement with the highest central orifice catheter gradients (mean difference, 1.0 +/- 3.1 and 0.9 +/- 1.5 mm Hg, respectively). A significantly better agreement between Doppler and catheter gradients at 30 mm was found for the Hancock valve, although Doppler peak and mean gradients were still slightly greater than catheter gradients. Doppler gradients exceeded catheter gradients by 18 +/- 10% (3.4 +/- 1.9 mm Hg) and 13 +/- 11% (2.1 +/- 0.9 mm Hg), respectively. When the catheter was pulled back through the valve, the highest gradients were found approximately 20 mm distal to the valve ring.(ABSTRACT TRUNCATED AT 250 WORDS)
منابع مشابه
Aortic Prosthetic Valves In Vitro A Manifestation of Localized Gradients and Pressure Recovery
To evaluate possible causes of discrepancy between Doppler and catheter gradients across prosthetic valves, five sizes (19-27 mm) of St. Jude and Hancock valves were studied in an aortic pulsatile flow model. Catheter gradients at multiple sites distal to the valve were compared with simultaneously obtained Doppler gradients. In the St. Jude valve, significant differences between Doppler and ca...
متن کاملEffect of prosthetic valve malfunction on the Doppler-catheter gradient relation for bileaflet aortic valve prostheses.
BACKGROUND Considerable discrepancies between Doppler and catheter gradients caused by localized gradients and pressure recovery have been reported for normal bileaflet aortic valve prostheses. METHODS AND RESULTS To examine whether this Doppler-catheter gradient relation is affected by prosthetic valve malfunction, a 19-mm CarboMedics aortic valve was simultaneously studied with continuous-w...
متن کاملContinuous wave Doppler echocardiographic measurement of prosthetic valve gradients. A simultaneous Doppler-catheter correlative study.
Studies correlating prosthetic valve gradients determined by continuous wave Doppler echocardiography with gradients obtained by cardiac catheterization have, to date, been limited to patients with mitral and tricuspid prostheses or have compared nonsimultaneous measurements. Simultaneous Doppler and catheter pressure gradients in 36 patients (mean age, 63 +/- 13 years) with 42 prosthetic valve...
متن کاملDoppler-Catheter Gradient Relation for Bileaflet Aortic Valve Prostheses
Background. Considerable discrepancies between Doppler and catheter gradients caused by localized gradients and pressure recovery have been reported for normal bileaflet aortic valve prostheses. Methods and Results. To examine whether this Doppler-catheter gradient relation is affected by prosthetic valve malfunction, a 19-mm CarboMedics aortic valve was simultaneously studied with continuous-w...
متن کاملContinuous Wave Doppler Echocardiographic Measurement of Prosthetic Valve Gradients
Studies correlating prosthetic valve gradients determined by continuous wave Doppler echocardiography with gradients obtained by cardiac catheterization have, to date, been limited to patients with mitral and tricuspid prostheses or have compared nonsimultaneous measurements. Simultaneous Doppler and catheter pressure gradients in 36 patients (mean age, 63+13 years) with 42 prosthetic valves (2...